English
2. Check on mounting screws for each part
At regular intervals check every part for loose mounting
screws and whether or not there are any air leaks.
Retighten any loose screws. Operating the equipment
with loose screws untightened will incur a hazard.
3. Inspecting the push lever
Check if the push lever can slide smoothly.
Clean up the sliding area of the push lever and use the
provided oil for lubrication from time to time. Lubrication
enables smooth sliding and simultaneously serves to
prevent the formation of rust.
4. Storing
○ When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
○ Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
○ When not in use, the Nailer should be stored in a warm
and dry place.
Keep out of reach of children.
5. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
CAUTION
Repair, modifi cation and inspection of HiKOKI Power
Tools must be carried out by a HiKOKI Authorized
Service Center.
This Parts List will be helpful if presented with the tool to
the HiKOKI Authorized Service Center when requesting
repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
MODIFICATION
HiKOKI Power Tools are constantly being improved
and modifi ed to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
COMPRESSOR
CAUTION
When the maximum, operating pressure of the air
compressor exceeds 8.3 bar (120 psi.), be sure to
provide a reducing valve between the air compressor
and nailer. Then, adjust the air pressure within the
operating range of 4.9 – 8.3 bar (70 – 120 psi.). If the
air set is installed, lubrication is also possible, thus
providing additional convenience.
OILER-FILTER-REDUCING VALVE (Air Set)
So that the equipment can be operated under an
optimum condition to ensure extended service life, it is
recommended to use an oiler fi lter reducing valve. Please
limit the length of the hose between the unit and the air set
to within 10 m when using (See Fig. 9).
APPLICABLE LUBRICANTS
Type of lubricant
Recommended oil
Motor oil
Turbine oil
10
Name of lubricant
SHELL TONNA
SAE10W, SAE20W
ISO VG32 – 68
(#90 – #180)
Noise Information
Noise characteristic values in accordance with EN 792-13,
JUNE, 2000:
The typical A-weighted single-event sound power level
The typical A-weighted single-event emission sound
pressure level at work station
Uncertainty KpA: 2.5 dB (A).
These values are tool-related characteristic values and
do not represent the noise development at the point of
use. Noise development at the point of use will for example
depend on the working environment, the workpiece, the
workpiece support and the number of driving operations,
etc.
Depending on the conditions at the workplace and the form
of the workpiece, individual noise attenuation measures
may need to be carried out, such as placing workpieces on
sound-damping supports, preventing workpiece vibration
by means of clamping or covering, adjusting to the minimum
air pressure required for the operation involved, etc.
In special cases it is necessary to wear hearing protection
equipment.
Vibration Information
The typical vibration characteristic value in accordance
with EN 792-13, JUNE, 2000: 3.00 m/s
5.50 m/s
(NR90AE(S1))
2
Uncertainty K = 1.5 m/s
2
This values is a tool-related characteristic value and
does not represent the infl uence to the hand-arm-system
when using the tool. An infl uence to the hand-arm-system
when using the tool will for example depend on the gripping
force, the contact pressure force, the working direction, the
adjustment of energy supply, the workpiece, the wrokpiece
support.
LWA,1s,d = 105 dB (A)
LpA,1s,d = 98 dB (A)
(NR90AD(S1))