E
lectrical supply
F
used mains electricity should be terminated with an isolator adjacent to the steam generator. The supply
should be rated according to the generator to be fitted and not less than the following:
P
ower
3.4kW
4.7kW
6.0kW
7.7kW
9.5kW
12 kW
14 kW
A
n isolation switch should be fitted in a convenient location outside the bathroom area so that the
generator can be switched off when not in use. Remove the vented top plate of the generator and co
into the terminal block as follows:
3 –phase
3,4 -- 14 kW
400 V - 415 V
Ajustes de fábrica
FACTORY SETT N
_
_____ _____
_
_____________________ __
3-phase
E
lectrical connections are only to be done by a licensed electrician.
*
) Walls made of heavy materials, such as concrete, brick or stone require a higher output to generate
sufficient heat. Ventilation must also be given extra power.
T
he required power output can be estimated using the fomula below.
V
olume (m3) x K1 x K2 = Required output (kW)
V
entilation
No ventilation
Acrylic walls
Light construction wall: + board tile
Heavy construction wall: stone, concre
Extra heavy construction
400V – 415V 3N~
5 Amp
7 Amp
9 Amp
12Amp
15Amp
19Amp
23Amp
N
L1 L2 L3
I G
__ ____ _____
L1 L2 L3
3,4 – 14 kW
230 V 3~
te + t e
il
230V-240V 1N~
230V 3~
15 Amp
20 Amp
12 Amp
26 Amp
15 Amp
33 Amp
19 Amp
-----
24 Amp
-----
30 Amp
-----
35 Amp
1-phase
N
3,4 / 4,7 / 6,0 / 7,7 kW
230 V - 240 V
Att. max. 7,7 k
_
___________________
FACTORY SETTING
Used only in specific electr
to be ordered separately from the factory
K1 = 0.75
K1 = 0.52
K2 = 1.00
K2 = 1.25
K2 = 1.50
K2 = 2.0
8 Amp
L1
W
______________
ical systems-
nnect
7