6. Operation
The equipment consists of an assembly with a
pump, which is encased in a shock absorbing
housing. For an optimal working position the
equipment comes with a lance and a non-slip
gun, whose shape and confi guration comply with
the applicable regulations.
6.1 Using for the fi rst time
Once you have completely assembled the pres-
sure cleaner and made all the connections, pro-
ceed as follows:
Open the water inlet. Press safety pin „a" (Fig. 2)
on the spray gun and pull back trigger lever „b"
(Fig. 2) in order to bleed the trapped air out of the
equipment.
Turn on the equipment by switching the On/Off
switch (Fig. 1/3) to "I".
Now activate the trigger lever (b).
Pressure switch:
Function of the pressure switch: The following
happens when the gun is switched off : the pres-
sure switch trips, the power supply is disconnec-
ted, the pressure switch switches off the pump,
and the high-pressure cleaner goes into stand-by.
As soon as you press the trigger lever (b), the
pump will restart. To turn off the pressure cleaner
completely, set the On/Off switch (Fig. 1/3) to
"OFF". When the pump pressure exceeds the
pressure of the pre-set pump valve, the surplus
liquid will return to the inlet system.
6.2 Using cleaning agent
Fill the cleaning agent container (10) with sui-
table cleaning agent.
The cleaning agent will be added automati-
cally in low-pressure mode.
Note:
Use only cleaning agents which are expressly
suitable for high-pressure cleaners.
6.3 Holder for the gun/accessories (Fig. 1)
The gun and accessories can be kept in the provi-
ded accessories holder (2) in order to save space
when not in use.
Anl_TC_HP_1334_SPK7.indb 19
Anl_TC_HP_1334_SPK7.indb 19
GB

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the mains power plug before star-
ting any cleaning work.
8.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could
attack the plastic parts of the equipment. En-
sure that no water can seep into the device.
8.2 Maintenance
8.2.1 Testing the water intake fi lter
Periodically check the intake fi lter in order to pre-
vent clogging, which could jeopardize operation
of the pump.
To do this, unscrew the coupling for the water inlet
hose from the device and clean the exposed inlet
sieve under running water.