8. Battery replacement

A message is sent to the CLT 8000 TYXAL + keypad to alert that the battery is empty.
The alarm control unit beeps each time the system is activated or deactivated, (or "battery defect" with the
speech synthesis system (requires the auto attendant to be enabled, see CLT 8000 TYXAL+ guide).
Switch the alarm control unit to MAINTENANCE mode
(see system guide)
Open the TYDOM 2.0 unit.
Unlock the unit.
2
1
Remove the top cover.
We recommend using SAFT LSH20 - 3.6 V batteries.
Handling the battery
Risk of fire, explosion and serious burns.
• Keep out of reach of children.
• Do not reverse the polarity.
• Do not open the battery system.
• Do not grind or pierce the parts.
• Do not short circuit the (+) or (-) terminals of the
battery by using conductive items.
• Do not subject to excessive mechanical stress.
• Do not expose the unit to water
or condensation.
1
2
Remove the bottom cover.
Remove the socket cover.
Using a screwdriver,
lift the 2 clips holding the top
cover.
Insert the battery, observing
the right polarity.
• Do not heat directly to more than 100°C (212°F),
solder or throw into a fire.
These unsuitable uses can cause leaks or sprays
of vaporised electrolyte
as well as a fire or explosion.
• Do not recharge.
• Dispose in compliance with the regulations in force.
46
2
1
SAFT
LSH20
3.6V