AIR MOVEMENT
Position heaters so there is no direct air movement on the heater.
Stir fans, inlets and tunnel doors should not blow directly on the units (During minimum ventilation, lock off
inlets that affect heater operation).
Check all heaters to be sure flame is not blowing outside the emitter.
Do not run heaters during tunnel ventilation.
Control end of heater should be towards tunnel fan end.
The gas supply inlet must be installed so that the gas supply hose is away from the surface of the heater.
Electrical supply must be installed so that electrical power cord is away from the surface of the unit.
The gas supply hose and the electrical power cord must not touch or rest on any surface of the heater
during operation of the unit or rest on the unit while the heater is being winched up or down.
THIS HOSE INSTALATION IS CORRECT
AIR FLOW
The gas supply installation shown in the illustration above allows the gas supply hose to hang AWAY from
the surfaces of the heater even during winching of the unit.
This is the CORRECT method for installing the gas supply hose.