The regulator has dissipation through internal
resistances. The upper part of the regulator
can heat up on windy days once batteries
have been charged.
Do not cover the upper part of the regulator -
the holes on the top cover must be
unobstructed for correct ventilation.
To install the regulator, lift the lower cover from the regulator (only the small
cover which forms a 90 degree angle) by removing the four screws that hold it in
place. This way, the regulator will be positioned as in the following illustration:
The regulator must be placed in a well ventilated area and
in vertical position at a height of approximately 1.20m
from the floor and a minimum of 50cm from batteries so as
to avoid contact with the gases these produce.
Bornay 600 – Rev 6.0 - P 48
WARNING:
The
regulator
has
resistance.
Do not cover upper
part.
Install in a well-ventilated
area.
The regulation control
box,
batteries
possible converter must
be allocated a central
location near to the
point of use and as near
as possible to each
other.
WARNING:
DO NOT invert polarity.
A change in polarity can
damage the regulator.
internal
and