5 Maintenance
For cleaning the outside of the unit, only use a dry, soft
cloth; never use chemicals or water which may get
inside the unit.
Due to the viscosity of the fog fluid and the high
vaporizing temperature, fog machines are susceptible
to clogging. After approx. 40 hours of operation, it is
therefore recommended to clean the unit with a fluid
consisting of 90 % distilled water and 10 % vinegar.
1) Disconnect the fog machine from the mains and
allow it to cool sufficiently.
2) Unscrew the fog output nozzle by means of a suita-
ble tool, then use vinegar to remove any deposits
on the nozzle.
3) Completely empty the tank.
4) Fill the tank with the cleaning fluid stated above.
5) Operate the unit with the cleaning fluid in a suffi-
ciently ventilated environment until the tank is
empty. (It is recommended to position the fog
machine in such a way that the fog will stream out
through an open window or door.)
6) Replace the nozzle.
7) Refill the unit with fog fluid and create fog for
approx. 3 minutes in order to remove any acid resi-
dues from the unit.
6 Specifications
Heating power: . . . . . . . . . . 1000 W
Heating-up time after
setting into operation: . . . . . approx. 4.5 minutes
Tank capacity: . . . . . . . . . . . 1.3 litre
Fog output: . . . . . . . . . . . . . approx. 141 m
Power supply: . . . . . . . . . . . 230 V~/50 Hz
Power consumption: . . . . . . 1000 VA
Ambient temperature: . . . . . 0 – 40 °C
Dimensions: . . . . . . . . . . . . 180 x 210 x 390 mm
Weight: . . . . . . . . . . . . . . . . 5.7 kg
Subject to technical modification.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
3