albatros ACTPL-S Manual De Uso página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Operating Instructions
OZONE CONTROL KEY
This key switches the OZONE function on and off.
When pressed and held down (for about 1 second)
the OZONE system switches on at maximum
power and the key surround lights blue.
The amount of ozone can be adjusted to vary
in cycles at three different levels (maximum -
medium - minimum - maximum - medium etc.).
When the OZONE function is in operation at
maximum power, the amount of ozone can be
reduced by one level by pressing the key briefl y;
at medium intensity the surround lights green.
To reduce the intensity further (to the minimum
setting), press the key briefl y once again; the
surround will light turquoise.
To return to maximum intensity, press the key
once more; the surround will light blue.
To switch off the OZONE system, press and hold
down the key for about 1 second.
The OZONE function can be selected only if the
AIRPOOL function is in operation.
ON/OFF SWITCH - UNDERWATER LAMP
Press this key to switch the underwater lamp on
and off. When the lamp is lit, the key surround
lights yellow.
CYCLICAL PROGRAMME CONTROL KEY
This key switches the cyclic massage programme
(at the selected massage intensity). When this key
is pressed and held down for about 1 second, the
CYCLICAL massage switches on at maximum
setting and the key surround begins to fl ash
yellow at maximum speed. This programme can
be selected only when the WHIRLPOOL and/or
AIRPOOL massage options (with or without
OZONE) are in operation.
The ON and OFF intervals can be varied in cyclical
sequence between three different intervals
(maximum - medium - minimum - maximum
- medium etc.).
When the cyclical massage option is in operation,
press this key briefl y to reduce the ON time by
one level, to medium setting. The key surround
will fl ash at medium speed. If the key is pressed
briefl y again, the ON time will be reduced further,
to minimum setting, and the key surround will
fl ash slowly.
Press the key once more to return to the maximum
ON time; the key surround will again fl ash at
maximum speed.
Press and hold down the same key for about 1
second to disactivate the CYCLICAL massage
function.
For ACTPLR-S and ACTPLR-P systems only:
The LYMPH DRAINAGE function cannot be
selected if the CYCLICAL massage option is
in operation.
Manuale Uso VS ACTPL-S/ACTPL-P - Code 10009717 - Edition 2 - 06/2007
Fast fl ashing = Maximum ON time
60 sec. massage ON - 15 sec. massage OFF
Medium fl ashing = Medium ON time
45 sec. massage ON - 30 sec. massage OFF
Slow fl ashing = Minimum ON time
30 sec. massage ON - 45 sec. massage OFF
LYMPH DRAINAGE CONTROL KEY
This key switches on and off the programme
which creates a cyclical, localized massage effect
starting from the feet then up the calves, the
systems only:
back of the thighs and the lower back, applying
ACTPLR-S
pressure for about one second in each position.
ACTPLR-P
The LYMPH DRAINAGE programme begins at
maximum intensity, and the key surround lights
blue. This option can be selected only if the
WHIRLPOOL and/or AIRPOOL massage function
is in operation.
The time for which the localized massage is
applied can be varied in cyclical sequence
between three different settings (maximum -
medium - minimum - maximum - medium etc.).
When the LYMPH DRAINAGE function is in
operation, press the key briefl y: the speed of
the cycle will decrease by one level and the key
surround will light green.
To reduce the speed further (to minimum power),
press the key briefl y once again; the surround
will light turquoise.
To return to maximum speed, press the key once
more; the surround will light blue.
If desired, the lymph drainage can be set to
remain localized on a particular part of the body by
pressing the same key twice in rapid succession.
The key surround will begin to fl ash, the colour
depending on the level selected at the time.
To resume cyclical operation of the lymph
drainage function, again press the key twice in
rapid succession.
To switch off the LYMPH DRAINAGE function,
press the key and hold down for about 1
second.
When the LYMPH DRAINAGE function is in
operation, the CYCLICAL MASSAGE option
cannot be selected.
Blue = maximum cycle speed: 5 sec.
Green = medium cycle speed: 8 sec.
Turquoise = minimum cycle speed: 12 sec.
Level of water in the tub (LED 1):
Led 1
When the level of water is not suffi cient for
operation of the hydromassage system, the light
is RED. When the level necessary for operation
of the system is reached, this light turns GREEN
and remains GREEN for the entire hydromassage
cycle.
Level of disinfectant in the tank (LED 2):
Led 2
This LED lights RED when the disinfectant tank
is empty, and GREEN when the tank is full.
"Start" key for DISINFECTION CYCLE
For ACTPUL-S and ACTPUL-P systems only
This key starts the disinfection cycle (see spe-
cifi c section)
2
English
Tabla de contenido
loading

Productos relacionados para albatros ACTPL-S

Este manual también es adecuado para:

Actpl-pActpul-sActpul-p

Tabla de contenido