Wire connections shown in Fig. 1 are described hereunder:
Terminals
Function
M+/M-
Motor
COM
SWO
Limit switches
SWC
BAR/BAR
SAFETY EDGE
PED
PEDESTRIAN
PHOTA
Open Photocell
PHOT
Photocell
STOP
STOP
P.P.
Step-by-Step
+COM
COMMON
SHIELD/
Antenna
ANT
FAST
Secondary
24V
Transformer
SLOW
0V
IICH
2°Ch radio
+ 24V -
24 VAC/DC
BLINK
Flashing light
SCA
SCA
ENCODER
Encoder
In case of power failure, an optional accessory to power the control unit is available.
The kit is composed of CB.24V battery charge card and two rechargeable batteries at 12V/1,2Ah, which can be fitted on
the back on the control unit container.
The CB.24V card must be connected between the secondary transformer and the 0/SLOW/24V/FAST inputs, as shown in
the diagram of Fig.2.
During mains powered operation, the DL2 green LED is switched on and the card maintains the battery charged.
If no mains power is available, the card powers the system through batteries, the DL1 red LED switches on.
A F10A fuse protects the control unit during operation with an emergency battery.
If no main power is available and batteries are down, both LED's are switched.
The buffer battery works and progressively runs down until it reaches the value of 18V. When this value is reached, the
battery is disconnected.
During operation in case of power failure, the output, 24VAC accessories of the control unit, is polarised.
CP.B24 CONTROL UNIT

WIRE DIAGRAM

Description
Quick connector for motor connection, 24VDC 120W max
Quick connector for limit switch connection.
COM: Common to limit switches
SWO: Input, OPEN limit switches (N.C. contact)
SWC: Input, CLOSE limit switches (N.C. contact)
Input, safety edge contact
Resistive edge: Closed "DAS" jumper
Mechanical edge: Open "DAS" jumper
If the safety edge is activated, the gate stops and the performs a movement reversion
for 3s
Input, pedestrian push-button (N.O. contact). It controls the partial opening of the gate
according to the value preset by TPED.
Input, photocell activated in the opening phase only
Input, photocell activated in both opening and closing phases
Input, STP push-button (N.C. contact)
Input, step-by-step push button (N.O. contact)
Common to all control inputs.
Antenna connection to the built-in receiver card
SHIELD: Shield/ ANT: Signal
Inputs, connection of the secondary transformer
FAST: Input, 23V, it powers the motor during operation at normal speed
23V: power supply of accessories
SLOW: Input, 15V, it powers the motor during braking
0V: Input, 0V
Output, second radio channel of the built-in radio receiver.
N.O. contact, power-free.
, power supply of accessories, 24VAC/0.5A max.
CAUTION: in the event of installation of the battery loader card CB.24V, the output
(without mains power supply) will feature a voltage of 24VDC - polarised.
Check the correct connection of devices.
Connection of the flashing light, 24VDC 15W max.
Open gate warning light 24Vac output.
Connector for connection of the position optic sensor (encoder).
EMERGENCY BATTERY