Fanox SIL-A Manual De Usuario página 120

Ocultar thumbs Ver también para SIL-A:
Tabla de contenido
1.8. Conducted disturbance
induced by radio frequency fields
1.9. Voltage dips, short
interruptions and voltage variations
1.10. Ripple on DC input power
port
1.11. Power frequency magnetic
field
1.12. 100KHz damped
oscillatory waves
1.13. Pulse magnetic fields
1.14. Damped oscillatory
magnetic fields
1.15. Ring wave immunity test
2. Product safety requirements
(including thermal short time
rating)
2.1. Impulse voltage
2.2. AC or DC dielectric voltage
2.3. Insulation resistance
2.4. Protective bonding
resistance
www.fanox.com
IEC 60255-26
Level 3, Applied voltage 10V, Frequency
0.15MHz - 80 MHz, AM Modulation 80% for
1KHz carrier sinusoidal signal, Dwell time 1s.,
IEC 61000-4-6
Test duration >10s.
IEC 60255-26
DC Voltage Dips: 40%, 130ms and 70%,
100ms, 3 times every 10s.
DC Voltage Interruption: 100ms, 3 times
IEC 61000-4-11
every 10s.
IEC 61000-4-29
IEC 60255-26
Level 4, Ripple 15%, 50Hz and 100Hz
IEC 61000-4-17
IEC 60255-26
Level 5, Continuous field strenght 100 A/m.
Short field strenght for a duration of 3s. 1000
A/m. Frequency 50Hz.
IEC 61000-4-8
Class 3, Repetition frequency 40Hz, Duration
IEC 61000-4-18
of each application 3s.
±2.5kV. Differential mode: ±1kV
IEC 61000-4-9
Field strenght 1000 A/m, Cadence between
pulses 40s.
IEC 61000-4-10
Level 5, Field strenght 100 A/m, Frequency
100KHz and 1MHz, Repetition frequency 40
trans./s at 100KHz, 400 trans/s at 1MHz,
Duration of each application 3s.
IEC 61000-4-12
Level 4, Line to earth for all terminals ±4kV.
Line to Line for all terminals excepts
Communication port ±2kV
IEC 60255-27
Each group to earth and with rest of the
groups in short-circuit ±5kV. Differential mode
for each one of the groups ±1kV
IEC 60255-5
IEC 60255-27
Each group to earth and with rest of the
groups in short-circuit 2kVac, 50Hz, 1 minute
IEC 60255-5
IEC 60255-27
500V applied between each group to earth
and with rest of the groups in short-circuit
IEC 60255-5
IEC 60255-27
Test current 2xIn, Test voltage 12Vac during
60s. Resistance shall be less than 0.1 ohm
Rev. 033
Common mode:
120/217