Specification And Performance Data Sheet - Gaggenau RF 411 Manual De Uso Y Cuidado

Ocultar thumbs Ver también para RF 411:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Specification and Performance Data
Sheet
Replacement Water Filter: Use CUNO Filter Model
9000 077 09 or 9000 077 104
The model was tested by NSF International with
reference to ANSI/NSF Standards 42 & 53
and certified for a reduction in the substances cited
below.
The concentration of the indicated substances which
are dissolved in water and penetrate the system was
reduced to a value below or equal to the permitted
limit value in accordance with NSF/ANSI 42
and 53 for water discharged out of the appliance.
Substance
Average in
inflow
Cysts *
166,500
Turbidity
10.7
Particle
5,700,000
class 1
particle
size > 0.5
to < 1.0 μm
Taste
1.9
of chlorine
and
turbidity
* Based on the use of Cryptosporium parvum ocysts.
Application Guidelines / Water Supply Parameters:
Water Pressure
Water Temperature *
Flow Rate
The system is to be installed and operated
according to the guidelines recommended by
the manufacturer.
The Filter is to be changed every 6-9 months.
Rinse the new Filter thoroughly for 5 minutes.
More detailed information can be found on
the Warranty Card.
18
Inflow
Waste water
concentration
concentration
Min. 50,000/l
1
11 x 1 NTU
0.3 l
At least
30.583
10,000 particles/ml
2.0 mg/l + - 10 %
0.05
30 - 120 psi
(207 - 827 kPa)
33 °F - 100 °F
(0.6 °C - 38 °C)
0.75 gpm (2.83 l/min.)
Note:
Even though the tests were conducted under standard
laboratory conditions, the actual performance may
deviate from these tests.
The system was tested and certified on model
9000 077 095 by NSF International with refer-
ence to ANSI/NSF Standard 53 for a reduction
in cysts and turbidity, as well as with reference
to ANSI/NSF Standard 42 for a reduction in
the taste and odor of chlorine.
Nominal particle class: I
Nominal service life:
739.68 gallons (2,800 liters)
Average
Max. permitted
reduction
concentration in
as %
waste water
99.99
99.95
97.10
0.5 NTU
99.52
> 85 %
97.3
> 50 %
Without appropriate disinfection before and after
connecting it to the system, this product should
NOT be used if the water is microbiologically
contaminated or if the quality has not been
ascertained. A system certified for cyst reduction
should be used for disinfected water which possibly
contains filterable cysts.
A one-year warranty is issued for the entire system
(except disposable cartridge). With reference
to disposable cartridges a warranty is issued for
material and processing faults only. As the service life
of disposable cartridges depends on the local water
conditions, no warranty is issued for them.
More detailed information on the prices of spare parts
is available from your appliance dealer or parts
salesman on site.
Manufactured by:
Cuno Engineered Products
1000 Apollo Road
Eagan, MN 55121-2240 U.S.A.
Max. waste
Min.
NSF test
water
reduction
as %
1
99.99
511077-03
0.49
95.42
511078-03
69.000
98.9
511079-03
0.06
96.84
511081-03
Tabla de contenido
loading

Este manual también es adecuado para:

Rf 413Rf 461Rf 463Rf 471Rf 463 rf 471

Tabla de contenido