ELITE 3000
8.4
CLEANING THE AIRLESS SPRAY GUN
Clean the spray gun after each use.
i
1. Rinse airless spray gun with an appropriate cleaning agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the airless spray gun.
INTAKE FILTER IN AIRLESS SPRAY GUN
1. Unclip the top of the trigger guard (1) from the gun head.
2. Using the bottom of the trigger guard as a wrench, loosen
and remove the handle assembly (2) from the gun head.
3. Pull the old filter (3) out of the gun head. Clean or replace.
4. Slide the new filter, tapered end first, into the gun head.
5. Thread the handle assembly into the gun head. Tighten
with the trigger wrench.
6. Snap the trigger guard back onto the gun head.
1
9
9.1
i
MINIMUM CHECK BEFORE EVERY STARTUP:
1. Check the high-pressure hose, spray gun with rotary joint,
2. Check whether the pressure gauge can be read.
CHECK AT PERIODICAL INTERVALS:
1. Check inlet and outlet valve according wear. Clean it and
2. Check all filter inserts (spray gun, suction system) clean it
9.2
Inspect the high-pressure hose visually for any notches or
bulges, in particular at the transition in the fittings. It must be
possible to turn the union nuts freely. A conductivity of less
than
1 MΩ must exist across the entire length.
3
Attention
2
SERVICING
GENERAL SERVICING
We strongly recommend having an annual check
carried out by technicians for safety reasons.
Please observe all the applicable national
regulations.
power supply cable with plug for damage.
replace worn out parts.
and replace if necessary.
HIGH-PRESSURE HOSE
Have all the electric tests carried by Titan Service.
The risk of damage rises with the age of the high-
pressure hose.
Titan recommends replacing high-pressure
hoses after 6 years.
CLEANING THE UNIT / SERVICING
19