ChefTop™ - BakerTop™
4.10 Cooking with Core Probe + Delta T
Temperature from 0°C to 260°C
In this case you have to set the desired temperature
at the core of the food and the Delta T (difference be-
tween the core and the chamber temperature)
CHAMBER TEMPERATURE =
CORE TEMPERATURE + SET DELTA T
In this way the chamber temperature will increase gradu-
ally, keeping the difference between the product core
temperature and the chamber temperature you set con-
stant during the cooking cycle. This kind of cooking will
allow you to obtain very soft and delicate cooking, espe-
cially useful for large joints of meat.
Core probe + 100°C ∆T
Core probe + 50°C ∆T
5. CONNECTION WITH THE EXTERNAL
WORLD
The digital control panel of the "ChefTop™" -
"BakerTop™" ovens has been preset to easily connect
the oven to the external world through the present and
future systems of communication: USB, Bluetooth™, se-
rial connections, etc.
ENGLISH
ENGLISH
11
11
Set core temperature
Time in minutes
Set core temperature
Time in minutes
The USB interface kit XC226 is available, and allows the
following functions:
•
Insertion of cooking programs.
•
Changes in operational parameters (ex: probe setting).
•
Diagnostics of problems.
•
Saving of the trends with regard to temperatures
inside the oven chamber or inside the blast chiller
chamber (necessary data for HACCP system)
•
Connection to a printer (HACCP)
You can find further information included in the kit.
6. ORDINARY MAINTENANCE
The appliance must be regularly serviced (at least once a
year) by a qualified Unox service technician.
Any maintenance operations must be carried only by a
qualified UNOX technician.
Before starting any maintenance operation, it is necessary
to disconnect the appliance from the electrical power
supply and allow it to cool down.
6.1 REPLACEMENT OF THE INTERNAL LAMP
To replace the internal lamp:
•
disconnect the appliance from the power supply and
allow it cool down.
•
remove the lateral supports
•
unscrew the glass cover and replace the lamp with
one with the same characteristics.
•
Inspect the lamp glass seal and replace if required.
•
screw the glass cover back in
•
reassemble the lateral supports
7. SPECIAL MAINTENANCE
All maintenance operations must be only be carried out
by a qualified UNOX technician.
Before starting any maintenance operation it is necessary
to disconnect the appliance from the electrical power
supply and allow it to cool down.
Removal of the back panel will allow access to all internal
components for service and maintenance.
7.1 RESETTING OF THE SAFETY THERMOSTAT
The appliance is supplied with a safety thermostat with a
manual reset. This safety thermostat is needed to protect
the appliance from overheating. When activated, it cuts
off the electrical supply to the heating elements and the
display panel shows the message "EF4".
This safety device can be found on the bottom part of the
back panel of the oven: to reset the thermostat,remove
the black cover and push in the small central pin.
If the safety thermostat activates again, contact your near-
est UNOX service centre.