4. O
PERATION
This product is not designed for continual use. Make sure there are regular breaks during operation to maximize the
life of your laser. Always disconnect the Scorpion™ Dual from power when not in use.
Control Panel
Operation
Menu Map
Mode
DMX Mode
Slave Mode
Remote Control
Test Mode
Sound-Active/Auto
Modes
Sensitivity
Configuration
(DMX)
Starting Address
Test Mode
Page 16 of 64
To access the control panel functions, use the four buttons located underneath the
display. When the product is on, the LED monitor on the rear panel will show the current
operating mode (standalone or DMX). The product will retain the last saved settings when
powered off.
Button
<MENU>
Selects an operation mode or backs out of the current menu option
<UP>
Scrolls up the list of options or selects a higher value
<DOWN>
Scrolls down the list of options or selects a lower value
<ENT>
Activates a menu option or a selected value
Programming Steps
001–503
SLA
rEN
tSt
Sou
Aut
S 0–S 9
Set the product in DMX mode to control with a DMX controller.
1.
Connect the product to a suitable power outlet.
2.
Turn the product on.
3.
Connect a DMX cable from the DMX output of the DMX controller to the DMX input
socket on the product.
When selecting a DMX starting address, always consider the number of DMX channels
the selected DMX mode uses. If you choose a starting address that is too high, you could
restrict the access to some of the product's channels.
The Scorpion™ Dual uses up to 10 DMX channels in DMX mode, which defines the
highest configurable address to 503.
If you are not familiar with the DMX protocol, download the DMX Primer from
www.chauvetlighting.com.
To select the starting address, do the following:
1.
Press <MENU> repeatedly until 001–506 blinks on the display.
2.
Use <UP> or <DOWN> to select the starting address.
3.
Press <ENTER>.
Activate the laser test pattern as follows.
1.
Press <MENU> repeatedly until tSt blinks on the display.
2.
Press <ENTER>.
Function
Description
Selects DMX starting address
Slave mode
Wireless remote control
Test pattern
Sound-Active mode
Auto mode
Sound sensitivity control
Scorpion™ Dual User Manual Rev. 1