Failure code
Warning D
E
W1.2
Temp. high
W2
Flow
W3
PWD User!
W4
Service !!
W6
On-Button
W9
Dump!!
W10
Failure type
FC
In the case of warnings the Warning LED [1-6] flashes yellow on the control panel, and the external light to be
connected to the control system by the customer flashes according to the table above; the system continues to
run. A warning message is displayed. If the cause of the warning is eliminated, the LED or Warning light goes
off. The warning message remains for a few minutes and disappears again. Warning messages can be deleted
by confirming with the [1-5] button.
Resetting the counter for the maintenance interval is only possible by service personnel.
Fault messages on the display
Extraction unit goes to Sleep mode. Start-up is not possible. Failure LED [1-7] illuminates on the control panel
and the external light to be connected to the control system by the customer illuminates red (permanent light).
The LED or Failure light goes off when the cause of the fault disappears.
A fault message is displayed which can be deleted using the [1-5] button.
Additional text (Servicetext) is displayed which can be individually defined (see chapter 8.7). Recommendation:
For example, enter the telephone number of the responsible service company here.
Failure code
Failure D
E
F1
Container
F2
Temp. high
F3
Temp. sen-
sor k
F3
Temp. sen-
sor a
Warning
Significance
light
Flashes 3
High temperature of blower
times - Pause
nozzle
Extraction unit runs at
reduced power
Regular flash-
Volume flow below 20 m/s
ing
Flashes 1
System is at plant level.
time - long
Pause
Flashes 1
Maintenance interval
time - long
exceeded.
Pause
Flashes 3
"ON" button was pressed <1
times - Pause
min is stuck.
Flashes 1
Container full.
time - long
Pause
Flashes 3
False frequency converter is
times - Pause
installed.
Significance
Container not inserted or inserted
incorrectly or fault with container
switch
Temperature in motor winding too
high
Short circuit temperature sensor in
motor winding
Broken wire temperature sensor in
motor winding
Turbo II M
Solution
Provide better cooling.
Reduce permissible number
of workstations.
Replace filter.
Switch off the device at the
main switch or wait 60 s
without input..
Contact service.
Have maintenance per-
formed.
Press "ON" button again.
Contact service.
Empty container (see chap-
ter 8.5 and 10.1)
Contact service.
Solution
Check container..
Check/ replace container switch
Contact service if fault occurs again.
Contact Service.
Contact Service.
Contact Service.
GB
23