10.4
Empty condensate container
CAUTION
Non-emptying of condensate container
Material damage, condensate can get into the in-
side of the control box
Empty condensate container regularly.
Open housing door [6-1].
Place container under the supply unit.
Slacken screw at condensate container [6-2].
When the condensate is drained completely, retight-
en the screws.
10.5
Replace electrical fuses
Annually: Have all fuses replaced by a qualified elec-
trician according to the circuit diagram.
In case of failure: only by qualified electrician!
– at the cap rail in the control cabinet, see fig. [7A].
– on the control cabinet door under the cover of the
control, see fig. [7B].
10.6
Check seals
When emptying every tank: Check container seal for
damage and replace if necessary.
10.7
Check hoses and hose clips
Check hoses under the front cover for damage and
replace if necessary.
Check hose clips for tightness (tightening torque
4±0.2 Nm)
11
Accessories
WARNING
Use of non-approved accessories and spare parts
Danger of explosion
For mobile dust extractors of design type 22 only
accessories and spare parts approved by Festool
especially for this purpose can be used - see
listed consumables, accessories list and spare
parts catalogue.
The order numbers for the accessories and filters
can be found in the Festool catalogue or on the In-
ternet at "www.festool.com".
12
Environment
Do not dispose of the device in house-
hold waste! Recycle devices, accesso-
ries and packaging. Observe applicable
national regulations.
EU only: In accordance with European Directive on
waste electrical and electronic equipment and imple-
mentation in national law, used electric power tools
must be collected separately and handed in for envi-
ronmentally friendly recycling.
Information on REACh: www.festool.com/reach
13
EU Declaration of Conformity
Exhaust turbines
Turbo II M - 8 WP
Turbo II M - 8 WP ATEX
Turbo II M - 14 WP
Turbo II M - 14 WP ATEX
Year of CE mark: 2013
We declare under sole responsibility that this prod-
uct complies with all the relevant requirements in
the following directives, standards and normative
documents:
Turbo II M - 8 WP: 2006/42/EU, 2004/108/EU, 2011/
65/EU, EN 60204-1, EN 55014-1, EN 55014-2, EN
61000-3-2, EN 61000-3-3, EN 60335-2-69 Anh. AA
Turbo II M - 8 WP ATEX: 2006/42/EC, 2004/108/EC,
2011/65/EU, 94/9/EG, EN 60204-1, EN 55014-1, EN
55014-2, EN 61000-3-2, EN 61000-3-3, EN 60335-2-
69 Anh. AA, EN 60079-0:2012, EN 60079-31:2009
Turbo II M - 14 WP: 2006/42/EC, 2004/108/EC, 2011/
65/EU, EN 60204-1, EN 55014-1, EN 55014-2, EN
61000-3-11, EN 61000-3-12*, EN 60335-2-69 Anh. AA
Turbo II M - 14 WP ATEX: 2006/42/EC, 2004/108/EC,
2011/65/EU, 94/9/E, EN 60204-1, EN 55014-1, EN
55014-2, EN 61000-3-11, EN 61000-3-12*, EN 60335-
2-69 Anh. AA, EN 60079-0:2012, EN 60079-31:2009
* Information on Turbo II M - 14 WP and Turbo II M
- 14 WP ATEX i.a.w. EN 61000-3-12 Anh.C:
This device does not satisfy the requirements of
EN 61000-3-12 Section 5. Therefore the device can
only be operated at its own supply network. If the de-
vice is connected to a public low voltage grid, approval
must be sought from the distribution system operator!
Talk to your electrician, they will support you here.
Festool GmbH
Wertstr. 20, D-73240 Wendlingen, Germany
Dr. Johannes Steimel
Head of Research, Development and Technical
Documentation
2014-11-04
Turbo II M
GB
Serial no.
10005102
10008622
10008621
10008623
27