Anleitung_TC_PG_2000_3_SPK8__ 25.08.14 09:51 Seite 11
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout (Fig. 1-4)
1 Tank indicator
2 Tank cover
3 2 x 230 V~ socket-outlets
4 Earth connection
5 Safety tripping element
6 Voltmeter
7 Oil filler plug
8 Oil drain plug
9 Oil shortage cut-out
10 On/Off switch
11 Choke lever
12 Reversing starter
13 Petrol cock

3. Proper use

The device is designed for applications operated with
a 230 V alternating current source. Be sure to
observe the restrictions in the safety instructions.
The generator is intended to provide electric tools
and light sources with electricity.
When using the device with household appliances,
please check their suitability in accordance with the
relevant manufacturer's instructions. In case of
doubt, ask an authorized dealer of the respective
appliance.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data

See warranty card of your country.
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the
quoted power output (2 min).
5. Before putting the machine into
operation
5.1 Electrical safety:
Electric supply cables and connected equipment
must be in perfect condition.
The generator is to be operated only with
equipment whose voltage specifications conform
with the generator's output voltage.
Never connect the generator to the power supply
(socket-outlet).
Keep the cable length to the consumer as short
as possible.
5.2 Environmental protection
Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
Recycle packaging material, metal and plastics.
5.3 Connecting to earth
The housing is allowed to be connected to earth in
order to discharge static electricity. To do this,
connect one end of a cable to the earth connection
on the generator (Fig. 4) and the other end to an
external earth (for example an earthing rod).
6. Operation
Important! You must fill up with engine oil (approx.
0.6 l) and fuel before you can start the engine.
Check the fuel level and top it up if necessary
Make sure that the generator has sufficient
ventilation
Make sure that the ignition cable is secured to
the spark plug
Inspect the immediate vicinity of the generator
Disconnect any electrical equipment which may
already be connected to the generator
GB