ART. 613 - MINIPOOL
PREPARING THE PLINTH
Make certain the supporting surface is perfectly level.
If the minipool is installed in the open (e.g. on a lawn),
prepare the plinth or slab with a suitably solid foundation
that will ensure the requisite stability.
1
B
ART. 614 - BUILT-IN MINIPOOL
PREPARING THE PIT
Leave a void (A) at least 40 cm wide on all sides of the
minipool, and 70 cm at the area marked (B), to ensure
sufficient freedom of access to the plumbing and electrical
equipment installed beneath the tub.
The void must be covered with a removable surround
carried on suitably sturdy supports; the surround must have
openings of at least 0.3 m
adequately ventilated.
Provide gulleys and a drain outlet (S) at the bottom of the
pit so that water will not collect and stagnate.
ROOM VENTILATION
If the minipool is installed indoors, the room or enclosure
must be properly ventilated.
2
PERMANENT CONNECTION OPTIONS
PLUMBING CONNECTIONS
O
- ø 40 mm drain outlet connection
(for fixed installation only - optional)
- Cable outlet for connection to a.c. supply
EMPTYING
The Teuco minipool has a drain valve.
The tub can be emptied simply by connecting a hose to the
valve, or alternatively, by making a permanent connection
to the main drain (O). In this instance it will be advisable
to install a trap with valve, which will serve as the foot
valve.
IMPORTANT: before making any permanent connection
to the main drain, contact the local authorities to check
on regulations governing the disposal of chemically
treated water.
FILLING
The recommended method of filling the Teuco minipool is
to use a hose, taking care not to immerse the end as this
could allow reflux of water back into the main.
IMPORTANT: if the intention is to connect the minipool
permanently to the water supply, suitable non-return
devices must be incorporated to prevent reflux back to
the water main.
Contact the local authorities before proceeding with this
type of installation.
12
PRE-INSTALLATION Art. 613-614
2
overall so that the pit will be
ELECTRICAL CONNECTIONS
The electrical power supply must be in compliance with
statutory regulations for the country of installation.
The appliance must be connected to the power supply by
way of an isolating switch with minimum contact
separation of 3 mm, sited away from areas 0, 1 and 2 (IEC
364-7-701).
Make certain the appliance is connected to the power
source by way of a residual current device with minimum
threshold ≤ 30mA.
The connection must include a connection to the earth
system and must be:
- permanent
- able to handle the rated current (see data plate)
- specified to liquids ingress protection category IPX5
PANELLED MINIPOOL (IEC 364-7-701)
ZONA 1
ZONA 2
ZONA 0
ZONA 0
1,5 m
2 m
BUILT-IN MINIPOOL (IEC 364-7-701)
ZONA 2
1,5 m
2 m
ZONA 0
ZONA 0
= h
ZONA 2
2 m
1,5 m
ZONA 1
ZONA 2
2 m
1,5 m