Specification ecoGEO B/C 3-12
Place of installation
Type of brine system
Heating
Application
HTR - High temperature recovery system
Integrated active cooling
Integrated passive cooling
Compressor range of modulation
Heating power
2
COP
, B0W35
Active cooling power
Performance
EER
2
, B35W7
Maximum unassisted DHW temperature
Maximum assisted DHW temperature
Noise emission level
Energy label / ηs with average temperature control
Heating outlet temperatura range
Cooling outlet temperatura range
Brine inlet temperature in heating mode range
Brine outlet temperature in cooling mode range
Operation limits
Cooling circuit pressure min / max
Production / Pre-load circuit pressure
Brine / Pre-load circuit pressure
Maximum DHW storage tank pressure
Refrigerant R410A load
Working fluids
Compressor oil type / load
1/N/PE 230 V / 50-60 Hz
Maximum recommended external protection
Control
electrical data
Transformer primary circuit fuse
Transformer secondary circuit fuse
1/N/PE 230 V / 50-60 Hz
Maximum recommended external protection
Maximum consumption
Electrical data:
Single phase
Maximum consumption
Starting current min/max
Correction of cosine φ
3/PE 400 V / 50-60 Hz
Maximum recommended external protection
Maximum consumption
Electrical data:
Three phase
Maximum consumption
Starting current min/max
Correction of cosine φ
Height x width x depth
Dimensions
and weight
Empty weight (without assembly)
1.
Replacing or combining the geothermal collector with one or more ecoGEO AU12 aerothermal units. Refer to the ecoGEO AU12 aerothermal
units manual for more detailed information.
2. In compliance with EN 14511, this includes the consumption of the circulation pumps and the compressor driver.
3. Considering brine and production flows of 2000 l/h.
4. Considering a heat ramp of 20°C to 50°C in absence of consumption.
5. Considering support provided by the emergency electrical resistor or the HTR system. Maximum DHW temperature with the HTR system can
be limited by the compressor discharge temperature.
6. In compliance with EN 12102, this includes the acoustic insulation kit of the compressor.
7. Starting current depends on working condition of the hydraulic circuits.
8. The admissible voltage range for proper operation of the heat pump is ±10%.
9. Maximum consumption can vary significantly according to working conditions, or if the compressor's range of operation is restricted. Refer
to the technical service manual for more detailed information.
10. Certification in process.
1
2
, B0W35
2
, B35W7
5
6
8
9
8
9
2
, B0W35
2
, B0W55
7
8
9
2
, B0W35
2
, B0W55
7
ecoGEO
Units
B/C1
-
-
Geothermal / Aerothermic / Hybrid
✓
-
✓
-
-
--
-
--
%
kW
-
kW
--
-
--
°C
°C
db
10
--
°C
10 to 60 (Max setpoint 60°C)
°C
4 to 35 (Min setpoint 7°C)
°C
°C
bar
bar
bar
bar
kg
0,9 (no HTR) / 1 (HTR)
kg
-
A
A
A
-
A
kW/A
kW/A
A
-
-
A
kW/A
kW/A
A
-
ecoGEO B: 1060x600x710
mm
ecoGEO C: 1804x600x710
B: 185
Kg
C: 246
53
User manual ecoGEO
ecoGEO
ecoGEO
ecoGEO
B/C2
B/C3
B/C4
Indoors
✓
✓
✓
✓
✓
✓
✓
✓
--
✓
✓
--
12,5 to 100
2,1 to 16
4,6
2,1 to 15
5,2
63
70
34 to 45
A+++ / 192%
-25 to +35
10 to 60
2 / 45
0,5 to 3 / 1,5
0,5 to 3 / 0,7
8 (Only for ecoGEO C)
1 (HTR)
POE / 0,74
✓
C16A
0,5
2,5
✓
C32A
4,2/18,6
5/21,7
2/8
0,96-1
✓
C16A
4,2/6,2
5/7,2
0,7/2,6
0,96-1
B: 193
B: 185
B: 193
C: 254
C: 246
C: 254