Operation of the device on a mains supply without ground conductor and on a socket with-
out ground conductor contact is only permitted if all national regulations for protective sep-
aration are observed.
Otherwise, this is considered gross negligence. The manufacturer shall not be held liable
for any damage arising from such usage.
If necessary, provide adequate earthing for the workpiece.
Switch off unused devices.
Wear a safety harness if working at height.
Before working on the device, switch it off and pull out the mains plug.
Attach a clearly legible and easy-to-understand warning sign to the device to prevent any-
one from plugging the mains plug back in and switching it on again.
After opening the device:
-
-
If work on live parts is required, appoint a second person to switch off the main switch at
the right moment.
Meandering weld-
If the following instructions are ignored, meandering welding currents can develop with the
ing currents
following consequences:
-
-
-
-
Ensure that the workpiece is held securely by the workpiece clamp.
Attach the workpiece clamp as close as possible to the area that is to be welded.
Position the device with sufficient insulation against electrically conductive environments,
e.g. Insulation against conductive floor or insulation to conductive racks.
If distribution boards, twin-head mounts, etc., are being used, note the following: The elec-
trode of the welding torch / electrode holder that is not used is also live. Make sure that the
welding torch / electrode holder that is not used is kept sufficiently insulated.
In the case of automated MIG/MAG applications, ensure that only an insulated wire elec-
trode is routed from the welding wire drum, large wirefeeder spool or wirespool to the wire-
feeder.
EMC Device Clas-
Devices in emission class A:
sifications
-
-
Devices in emission class B:
-
EMC device classification as per the rating plate or technical data.

EMC measures

In certain cases, even though a device complies with the standard limit values for emis-
sions, it may affect the application area for which it was designed (e.g. when there is sen-
sitive equipment at the same location, or if the site where the device is installed is close to
Discharge all live components
Ensure that all components in the device are de-energised.
Fire hazard
Overheating of parts connected to the workpiece
Irreparable damage to ground conductors
Damage to device and other electrical equipment
Are only designed for use in industrial settings
Can cause line-bound and radiated interference in other areas
Satisfy the emissions criteria for residential and industrial areas. This is also true for
residential areas in which the energy is supplied from the public low-voltage mains.
39