Truck-Mounted Charging System; Operation; Power Status Led Indicators; Battery Led Indicators - MSA EVOLUTION 5000 Manual De Instrucciones

Ocultar thumbs Ver también para EVOLUTION 5000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Truck Mounted Charging System

7. Operation

To charge the TIC and spare batteries using the EVOLUTION
5000 Truck-Mounted Charging System make sure the TIC
charging pins and cradle are clean and free from debris.
1. Place the TIC into the charging cradle with the display
facing outward; secure the unit with the straps on the
charging cradle.
2. If charging a spare battery, place the battery into the slot
provided and secure it with the rubber retainer.
The power LED indicator should always remain green when
the power source is ON and properly connected. When the
Truck-Mounted Charging System is correctly installed, the
status indicators will light as follows:

Power Status LED Indicators

Off
System Fault
Green
Power ON/
System Operational

Battery LED Indicators

Off
No Battery Installed
Green
Charge Completed
Fast blinking,
Charging
Green
Slow blinking,
Charge Pending
Green
Red
Fault
Any LED indication other than those listed indicates faulty
operation and the unit must be returned to MSA for service.
Note: For optimal performance, the battery charger should
be operated at temperatures between 10 to 30 °C (50 to
85 ° F). Charging batteries outside this temperature range
may result in a charging error and/or premature battery
degradation.
Charging batteries in environments greater than 38 °C
(100 °F) may result in premature termination of charge.
The charging cycle takes approximately 2.5 hours to
completely charge a single battery or five hours when
charging two completely discharged batteries.
14
Fig. 19: EVOLUTION 5000 and Truck-Mounted Charging
System

Specifications

Dimensions
Width
Height
without camera
Height
with camera
Depth
Weights (without
without camera
mounting kit)
with camera
Weight Mounting Kit only
Voltage Range
12.5–26.0 V DC

8. Installation

Getting Started

The EVOLUTION 5000 TIC Truck-Mounted Charging System
must be correctly installed before use. Read all installation
instructions thoroughly before starting actual installation.

What you will need:

Electric drill
5 mm and 7 mm drill bits
6 mm tap
Phillips head screwdriver
Stainless steel bolts (4)
5-amp in-line fuse
Master ON/OFF switch
Strain relief bushing for power supply cable
Mounting kit (provided) – Fig. 20 –, including 3 meters/
10 ft. power supply line
GB
265 mm (10.4 in)
155 mm (6.1 in)
230 mm (9.1 in)
145 mm (5.7 in)
770 gr. (1.69 Ibs)
2070 gr. (4.56 Ibs)
310 gr. (0.68 Ibs)
GB
Tabla de contenido
loading

Tabla de contenido