Oe9905 P4 Circuit Board Connection - CalSpas Portable Spas Manual Del Propietário

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

OE9905 P4 Circuit Board Connection

From RCD Box
Brown - NEUTRAL
Black - HOT
Yellow - GROUND
BLUE (Neutral)
GREEN/
YELLOW
(Ground)
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
1 x 32 Amp
3 Wires (1 Line + 1 Neutral + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
Service 2:
Brown - NEUTRAL
Black - HOT
Yellow - GROUND
From RCD Box
Service 1:
Brown - NEUTRAL
Black - HOT
Yellow - GROUND
BLUE (Neutral)
GREEN/
YELLOW
(Ground)
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
For each service:
1 x 32 Amp
3 Wires (1 Line + 1 Neutral + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
2012 Portable Spa
LTR20121001, Rev. A
Use X-P CE or X-P231 CE
Expander for Pump 3 1-Speed
J5
K2
J3
F2
J98
FUSE T0.3A
K3
J97
J97
F5
240V
W15
FUSE T30A 480V
J32
J32
F6
J99
J99
J53
J53
J23
Balboa
BALBOA INSTRUMENTS, INC.
GL2000 TC MACH 3
P/N 22898 REV D
COPYRIGHT 2006
F7
TB1
MADE IN U.S.A.
BROWN (Hot)
J27
J2 J2 J27
J93
FUSE T30A 480V
W3
J28
J96
J26
J68
J68
W4
K7
J57
J59 J58
J101
J101
J100
J100
H 2
HTR
HTR1
H
F1
Heater rated @ 230V
3.0 kW
J8 must be Jumpered
Use X-P CE or X-P231 CE
Expander for Pump 3 1-Speed
J5
K2
J3
F2
J98
FUSE T0.3A
K3
J97
J97
F5
240V
W15
FUSE T30A 480V
J32
J32
F6
J99
J99
J53
J53
J23
BALBOA INSTRUMENTS, INC.
Balboa
GL2000 TC MACH 3
P/N 22898 REV D
COPYRIGHT 2006
F7
TB1
MADE IN U.S.A.
BROWN (Hot)
J27
J2 J2 J27
J93
FUSE T30A 480V
W3
J28
J96
J26
J68
J68
W4
K7
J57
J59 J58
J101
J101
J100
J100
H 2
HTR
H
HTR1
F1
Heater rated @ 230V
3.0 kW
J8 must be Jumpered
J36
J41
J41
J4
J8
3.0kW
J81
J17
TST
K1
MAIN
J45
J45
PANEL
J2
K9
T1
K4
W1
J31
J31
MAIN
J30
J30
PANEL
J1
J12
MAIN
J55
J56
PANEL
F4
J9
K11
K10
AUX
PANEL
RTC
AUX
PANEL
K6
K8
Enabled
J69
J60
ADCM
REMOTE
J20
EXT RELAY J6
CFG
J90
SWITCHBANK A
SWITCHBANK B
J13
J15
J17
J22
J82
J24
EXT 2S P3
AUX F ALARM
SEN A
VAC
SEN B
Configuration
Settings
Enabled
DIP Switch A2 can be ON.
O
N 1
2
3
4
5
6
7
8
9 10 11 12
DIP Switch A3 and A4 must be OFF.
DIP Switch A11 must be ON.
J36
J41
J41
J4
J8
3.0kW
J81
J17
TST
K1
J45
J45
MAIN
PANEL
J2
K9
T1
K4
W1
MAIN
J31
J31
J30
J30
PANEL
J1
J12
MAIN
J55
J56
PANEL
F4
J9
K11
K10
AUX
PANEL
RTC
AUX
K6
K8
PANEL
Enabled
J69
J60
ADCM
REMOTE
J20
EXT RELAY J6
J90
CFG
SWITCHBANK A
SWITCHBANK B
J13
J15
J17
J22
J82
J24
EXT 2S P3
AUX F ALARM
SEN A
VAC
SEN B
Configuration
Settings
Enabled
DIP Switch A2 can be ON.
O
N 1
2
3
4
5
6
7
8
9 10 11 12
DIP Switch A3 and A4 must be OFF.
DIP Switch A11 must be ON.
J1
J3
GREEN/
YELLOW
(Ground)
BROWN
(Hot)
BLUE (Neutral)
J1
J3
www.calspas.com
9
Tabla de contenido
loading