6
Controls & Connections
Internal
A
HALF/FULL switches
These switches are used to configure wordclock operation when the DS2416
is used as a wordclock slave and receives its wordclock from the AX16-AT. IO-
A and IO-B can be set individually. In the FULL position, the DS2416 derives
its wordclock from the source selected using the ADAT/THRU switches.
Normally, these switches should be set to HALF, the default setting, in which
case the DS2416's wordclock source is always an ADAT IN connector regard-
less of the ADAT/THRU switch settings. This is convenient when switching
between the ADAT and THRU (AX44 or other device) connectors, because
you don't have to change the wordclock settings.
When an external device connected to the A IN connector is used as the
wordclock master, that device must be turned on and configured correctly for
wordclock master operation. If, for some reason, the external wordclock is
lost, the THRU connectors are checked for a usable wordclock, and if one is
not found there either, the DS2416 stops functioning.
(To use an external device as the wordclock master, you must connect it to the
A IN connector.)
B
IO-A connector
This connector connects to the IO-A connector on the DS2416 using the sup-
plied 20-pin connection cable.
AX16-AT—Owner's Manual
1
23
45
(PCI mounting)