SPECIFICATIONS AND LIMITATIONS

INCOMING WATER SUPPLY
pH
Water Pressure
Total Dissolved Solids (TDS)
Temperature Air and Water
Hardness
Iron Content
SYSTEM
Production Capacity Membrane Rating
*NOTE: These specifications are not the certified results and can vary greatly depending on feed water makeup,
i.e. pressure, temperature, TDS, and hardness. See Performance Data Sheet for the actual WQA Certified results
under standard test conditions on page 25. Regular maintenance and filter replacement are necessary for system's
performance and longevity.

WARNINGS

1. Only use with potable water supplies (Water
must be microbiologically safe).
2. Installation of R/O system must Comply with
state and local laws and regulations.
3. Check for leaks after installation or service
as system is reaching standard operating pres-
sure and temperature. Check for leaks peri-
odically thereafter. A system may be inad-
vertently moved or jarred while other items
are moved under the sink. If a fitting is acci-
dentally loosened, a leak could result causing
damage to your cabinet.
4. Do not let system freeze. Allow to warm up
to room temperature before installing. Best to
be installed indoors with air temperature be-
tween 60° - 85° F.
5. Attach to cold water supply only.
6. Never drain R/O tank completely without
first turning off the refrigerator ice maker.
7. Air-gap faucet may cause a slight noise at first
but noise should diminish in about a week. If
noise continues, adjusting drain clamp may
help reduce noise. Also, install faucet so
air-gap faucet hole will drain into the sink if
drain line gets plugged from obstruction in
the drain line.
4
| Krystal Pure™ | Reverse Osmosis System Manual
System Dimensions
Storage Tank Dimension
Rejection Rate
Storage Capacity
3 min. to 11 max.
40 PSI min. to 85 PSI max.
2000 PPM max.
40° F min. to 110° F max.
Water Softener Recommended over 10 GPG
<1 PPM max.
16" × 15.5" × 7"
15.5" × 11"
Up to 98% TDS*
Up to 3.2 Gallons*
24 gallons per day*
8. This reverse osmosis system contains a re-
placeable component critical to the efficien-
cy of the system. Replacement of the reverse
osmosis component should be with one of
identical specifications, as defined by the
manufacturer, to assure the same efficiency
and contaminant reduction performance.
9. Failure to follow recommended service in-
tervals or use of filters and parts other than
those recommended by the manufacturer
may void warranty.
10. Drain R/O tank completely at least twice a
year. If daily use averages less than a gallon
per day, drain every two weeks. (See page 3
for Many Uses).
11. We recommend having all porcelain/enam-
el-coated sinks professionally drilled.
12. Sanitizing most R/O systems on a yearly basis
is important for reducing bacteria build-up.
13. All membrane performance and life cycles
may be affected by severe water conditions.
Varying mineral content like hardness and
iron will require varying filter change inter-
vals. Some customers choose pretreatment
options like water softening or iron reduction
systems to protect the entire home.