PERFORMANCE DATA SHEET NSF/ANSI 58
REVERSE OSMOSIS SYSTEM MODEL NUMBERS: KR5, KR10 & KR15
REPLACEMENT TREATMENT COMPONENTS: SEE STEP 9, PAGE 8
GENERAL INSTALLATION, OPERATION & MAINTENANCE REQUIREMENTS
❱ Do not use with water that is microbiological-
ly unsafe or of unknown quality without ade-
quate disinfection before or after the system.
❱ This reverse osmosis system contains a replace-
able treatment component critical for effective
reduction of total dissolved solids. The product
water shall be tested periodically to verify that
the system is performing properly.
❱ While testing was performed under standard
laboratory conditions, actual performance
may vary.
PERFORMANCE CLAIMS
Substances
TDS
Barium
Trivalent Chromium 0.3 ± 10%
Cadmium
Copper
Fluoride
Lead
Radium
Selenium
Turbidity
Pentair Membrane 655006-00 RODTP Contaminant Reduction Information for PDS
SYSTEM SPECIFICATIONS
Daily Production Capacity 7.7
Rejection Rate 93.3%
Storage Capacity 2.6 gallons
Recovery Rating* 22.4%
Efficiency Rating* 11.7%
System Weight 27 lbs.
System Dimension 16" x 15.5" x 7"
Storage Tank Dimension 15.5" x 11"
Min./max. pressure 40 – 85 PSI
Min./max. temperature 40° - 110° F
14
| Krystal Pure™ | Reverse Osmosis System Manual
Required Influent
Challenge Concen-
tration (mg/L)
750 ± 40 mg/L
10.0 ± 10%
0.03 ± 10%
3.0 ± 10%
8.0 ± 10%
0.15 ± 10%
N/A
0.10 ± 10%
11 ± 1 NTU
❱ See Owner's manual for Manufacturer's limit-
ed warranty.
❱ This system has been tested and shown to
operate at its calculated recovery rating and ef-
ficiency rating under standard test conditions.
❱ Chlorine in the influent water may affect the
R/O membrane polymers.
❱ See Owner's manual for complete installation/
operation and maintenance requirements,
as well as user responsibility and parts and
service availability.
Maximum Permis-
sible product water
concentration (μg/L)
187,000
2000
100
5
1300
1500
10
N/A
50
0.5 NTU
he concentration of the indicated substances in
T
water entering the system was reduced to a con-
centration less than or equal to the permissible
limit for water leaving the system, as specified in
NSF/ANSI 58.
* Performance indicator. The product water shall
be tested regularly to verify that the system is per-
forming properly. Testing can be accomplished
by contacting the service company that installed
your R/O system or an authorized dealer. If a ser-
Minimum Actual
Average Actual
Percent Reduc-
Percent Reduction
tion
87.1
93.3
95.4
96.6
97.7
98.5
98.4
98.7
99.0
99.3
91.0
94.5
98.8
99.0
95.4
96.6
95.9
97.3
99.00
99.1
This system has certified by WQA
to NSF/ANSI 58 for the reduction
of substances below as verified and
substantiated by test data.