FIGURE 1

faucet stem
F
slot washer
white spacer
washer
lock washer (optional)
9/16" nut
5/8" adapter fitting
× 3/8" tube adapter
fitting
base of the faucet). Unscrew the coupling nut.
Place rubber washer into the plastic easy tap
faucet adapter and screw adapter onto location
of coupling nut. Hand-tighten, then tighten one
more complete turn with a wrench. Re-attach the
supply line to the adapter with the coupling nut.
Leave the cold water off.
CAUTION:
1. When tightening easy tap, make sure the tube
to which you are attaching the easy tap is not
twisted. Use two wrenches to hold existing
tube while tightening the easy tap adapter.
2. Examine existing cone shaped washer on wa-
ter supply tube, adjust or replace if damaged
or worn (not included).
3. If self-piercing valve is used instead of easy
6
| Krystal Pure™ | Reverse Osmosis System Manual
countertop
A
B
tap, attach to hard copper tubing only. Do not
over tighten screws (see instructions on pierc-
ing valve package, not included).
NOTE: Push-In style fittings are designed for ease of use.
Simply push the tubing in until it seats. Give a tug on it to
make sure it is secure. Insert red locking clip between fit-
ting and collar. If you need to remove the tubing, remove
the red locking clip, hold the locking ring collar against the
fitting while pulling out the tubing. No inserts or nuts are
used with the Push-In style fittings.
STEP 4 DRAIN SADDLE CLAMP
INSTALLATION
Location of Drain Clamp
1. Sink With Disposal: Select location to place
drain saddle clamp. Best choice is the verti-
cal pipe as near the sink as possible making
certain that the drain clamp is above the hor-
izontal garbage disposal waste pipe. When
connecting the black drain tube to drain saddle
clamp keep the tube run as straight as possible
and that there are no dips, loops, low spots or
kinks (See D in Figure 2 on page 7). Also, to
reduce noise, assure that R/O drain line enters
the vertical pipe from a direction other than the
direction of entry of the garbage disposal pipe.
Or
2. Sink Without Disposal: Best choice is the ver-
tical pipe about 4" above the water level in
the trap.
To Install:
Drill a 3/8" hole through one side of the drain-
pipe. Align the hole in the drain clamp with the
hole in the drainpipe. Tighten down the drain
clamp snugly so it will not move on drainpipe.

STEP 5 STORAGE TANK PREPARATION

1. Wrap the threads on top of the tank with 6
wraps of Teflon tape (do not use any type of
pipe compounds).
2. Screw tank ball valve onto the top of the
tank (approximately 4 to 5 full turns, do not
over-tighten). Check for leaks once R/O is
pressurized and while tank is filling and again
when tank is full.
3. Tank is pre-charged with air pressure. Tank
can be laid on its side if necessary (tank will
hold approximately 2 to 3 gallons of R/O wa-
ter depending on water pressure, tank posi-
tioning, and tank air pressure).
4. Tank pressure can be increased to improve wa-
ter flow to the faucet or refrigerator. Air pres-