Specifications & Limitations; Installation Inspection - Krystal Pure KS5 Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS AND LIMITATIONS
Total Grain Capacity: KS15HE
Maximum Ferrous Iron ("clearwater iron" only)**
Maximum flow rate to drain during
Water Pressure Drop at 5 GPM¹
SourceSelect™, Bypass Valve Size
Salt/Potassium Storage Capacity
(salt recommended: 99.99% pure pellets
Approximate Shipping Weight (with no salt)
*Efficiency: An efficiency rated water softener is a
DIR softener which also complies with specific perfor-
mance specifications intended to minimize the amount
of regenerant brine and water used in its operation. Effi-
ciency rated water softeners shall have a rated salt effi-
ciency of not less than 3350 grains of total hardness ex-
change per pound of salt (based on NaCl equivalency)
(477 grams of total hardness exchange per kilogram of
salt), and shall not deliver more salt than its listed rating.
The efficiency rating is only valid at the factory default
salt dosage and maximum service flow rate. Efficiency
is measured by a laboratory test described in NSF/ANSI
44. The test represents the maximum possible efficien-
cy that the system can achieve. Operational efficiency
is the actual efficiency achieved after the system has
been installed It is typically less than the efficiency due
5 • 02/17 KPWS
Total Grain Capacity: KS5
Efficiency*
Total Grain Capacity: KS10
Efficiency*
Efficiency*
Maximum Water Hardness
Minimum pH
Regeneration Time
regeneration: KS5
Water Pressure
Service Flow Rates: KS5
Temperature
Drain Line Size
Electrical Requirements***
System Dimensions:
Media Tank With Valve: KS5
Brine Tank: All
for maximum performance)
KS5 • KS10 • KS15HE
19,202 @ 4.7 lbs. of salt (using white injector)
24,145 @ 7.5 lbs. of salt
27,546 @ 10.5 lbs. of salt
4,100 grains/lb of salt @ 4.7 lbs. salt setting
20,483 @ 5.0 lbs. of salt (using white injector)
28,263 @ 10.0 lbs. of salt
30,865 @ 14.0 lbs. of salt
4,100 grains/lb of salt @ 5.0 lbs. salt setting
21,411 @ 5.0 lbs. of salt (using h injector)
42,354 @ 13.5 lbs. of salt
50,968 @ 22.5 lbs. of salt
4,330 grains/lb of salt @ 5.0 lbs. salt setting
24-60 Grains Per Gallon
1-10 PPMS
7
Approximately 80 – 120 Minutes
1.8 GPM
KS10
2.2 GPM
KS15HE
2.7 GPM
40 Min. –100 Max. PSI 85 PSI day time pressure
6.0 GPM @ 11 PSI pressure drop
KS10
9.4 GPM @ 11 PSI pressure drop
KS15HE
11.1 GPM @ 15 PSI pressure drop
0.6-1.0 PSIG
: 40° to 140° F •
air
¾" or 1"
½" (under 20' run and lower than 10' vertical at
60 PSI)
¾" (over 20' run or over 10' high, or over 7 GPM
backwash rates)
Continuous 110 Volt, 60 Cycles/2volt/24volt
8" dia. × 52" high
KS10
9" dia. × 56" high
KS15HE
10" dia. × 62" high
11" square × 34" high
150 lbs.
100-140 lbs.
to individual application factors including water hard-
ness, water usage, and other contaminants that reduce
the softeners' capacity.
**Iron can be in several forms, pretreatment will be nec-
essary if certain types of iron are encountered.
***Continuous means to a 110 outlet that has continu-
ous voltage not able to be turned off be a light switch.
These systems are efficiency rated and conform to
NSF/ANSI 44 for the specific performance claims as
verified and substantiated by test data.
No reduction of specific contaminant claims
¹Intermediate flow rates do not represent the maximum
service flow rate used for determining the softener's
rated capacity and efficiency. Continuous operation at
flow rates greater than the maximum service flow rate
may affect capacity and efficiency performances.
: 40° to 110°F
water
Tabla de contenido
loading

Este manual también es adecuado para:

Ks10Ks15heKs64he

Tabla de contenido