ENGLISH
2.7
Operating panel (fig. 7)
A
Reset button + indicator
B
Gas connection
C
Connection point for room thermostat
D
Connection cable
E
Selector switch:
-
0 = Off
-
1 = Heat
-
2 = Ventilate (not heat)
2.8
Accessories
Room thermostat
Outside air suction hose
Outside air feed-through
Moveable undercarriage (GA 60 and GA
85)
GA 42-60-85-110
GA 24-42-60-85-110
3

PREPARATIONS

3.1
Removing the packaging
1. Remove packaging from the heater.
3.2
Installation
1. Make sure that the heater has a stable
set-up.
The heater can be positioned both
horizontally and vertically (blowing up
or down).
When positioning the heater, take the
minimum distances (H
floor and the ceiling into account (see
fig. 11).
2. Hang the heater on the suspension eyes.
Warning
3. Connect the delivered gas hose with the
pressure controller (A) and the hose-
breaking protection (B) to the gas bottle,
for GA 42 see fig. 8, for GA 60-85-110
see fig. 9.
4. Connect the other side of the hose to the
gas supply of the heater.
40.020.947 - rev. 04 - 2011
40.020.947 - rev 05 - 2016
English
) unto the
min
Horizontal: a minimum of 0.2 m
above the floor.
Vertically blowing down: a
minimum of 2.15 m above the
floor (for GA 110 min. 1.70 m).
Vertically blowing up: a minimum
of 2.15 m below the ceiling (for
GA 110 min. 1.70 m).
Always place the magnet valve M
(see fig. 11) vertically (contact
your dealer).
Connect the heater exclusively to
the gas bottle using the delivered
hose with pressure controller and
hose-breaking protection.
Use gas bottles exclusively in a
standing position.
Do not place the gas bottles in
the hot air flow.