Paragraph 2 – Dosage Proportional to the pH (factory setting)
Programming
PROG
Configuration
Pump Funtions
-‐
+
Pump
Functions
pH Measure
-‐
Setpoint
-‐
7.00 pH
-‐
Setpoint Type
Acid
-‐
-‐
Prop. Band
-‐
0.50 pH
-‐
Alarm Band
-‐
2.00 pH
-‐
O.F.Alarm
-‐
0m
-‐
Resolution
-‐
0.01
-‐
Probe Calib.
-‐
On
Temperature Man.
Temperature Man.
25 °C
25 °C
-‐
Temperature Man.
77 °F
Display during Operation
•
Setpoint type;
Acid/Alka
Alarms and statuses
• Cal = calibration not
completed
• Lev = Level alarm
• Flw = Flow alarm
•
• Alm = Measurement
•
outside Alarm Band
•
• OFA = O.F.A. alarm
Hayward Flow Control
+
+
+
+
+
+
+
-‐
+
-‐
<-
-‐
+
Flow sensor status
pH measurement value
Alca
F F
F
7.00pH
Lev
Stop
P100%
Current dosage value
(depends on the selected unit
of measurement)
Pump status
•
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
www.haywardflowcontrol.com
The pump measures and controls the pH of a solution,
programming
in
proportional band and alarm band
Set-point type: acid
s/m
m a x
flo w-‐ra te
0
Set-point type: alkaline
s/m
m a x
flo w-‐ra te
0
Ala rm
Ba nd
It is also possible to programme:
- the O.F.A. (Over Feed Alarm) time in minutes, or rather a
time beyond which an alarm signal is triggered if the pH
value does not reach the set-point.
- The measurement resolution (1 or 2 decimal points)
- Deactivation/activation of the calibration procedure
- Manual temperature value in ºC (default) or ºF
The maximum frequency can be modified during operation, by
pressing the
flow, or the
Percentage, Frequency,
l/h, Gph, ml/m
(depends on the selected unit of measurement)
•
Operation
sequence:
set-point,
Pro p o rtio n a l
Ba n d
Pu m p
O ff
Ala rm
Ba nd
Ala rm
Ba nd
Pro p o rtio n a l
Ba n d
Pu m p
O ff
Ala rm
Ba nd
keys at the same time to increase the
keys to decrease it.
Display during Setting (MODE key)
Displays in sequence
•
SP = Setpoint value
•
BP = Proportional band value
•
BA = Alarm band value
•
OFA = O.F.A. value
•
Temp = Temperature value
SP
7.00pH
4.50pH
P100%
Maximum set dosage value
Percentage, Frequency, l/h, Gph, ml/m
1-888-INDL (1-888-429-4635)
set-point
type,
p H
1 4
p H
1 4
Measurement value
ZRDIOM
Pg. 4 of 11