2.5
Aprobaciones de Agencia
These units are in compliance with the EMC directive 2004/108/EC, the PED directive 97/23/EC and the ATEX directive 2014/34/EU.
Explosion Proof
US/Canada:
FM16US0357X/FM16CA0168X
Class I, Div 1, Group B, C and D, T4
Ta = -40°C to +70°C
Type 4X, IP67
Flame Proof:
Flameproof US/ Canada:
Class I, Zone 0/1, AEx db IIB + H2 T1...T6 Ga/Gb (US)
Class I, Zone 0/1, Ex db IIB + H2 T1...T6 Ga/GB (Canada)
Ta = - 40 C to +70 C IP 67
ATEX FM14ATEX0059X:
II 1/2G Ex db IIB+H2 T6...T1 Ga/Gb
Ta=-40°C to +70°C
IP67
IEC- IEC Ex FMG14.0028X
Ex db IIB+H2 T6...T1 Ga/Gb
Ta=-40°C to +70°C
IP67
Intrinsically Safe
US/Canada:
FM16US0357X/FM16CA0168X
Class I, II, III, Div 1, Group A, B, C, D, E, F, G, T4,
Class I, Zone 0 AEx ia IIC T4 Ga
Class I, Zone 0 Ex ia IIC T4 Ga
Ta =-40°C to + 70°C
Type 4X, IP67
ATEX – FM14ATEX0059X:
II 1 G Ex ia IIC T4 Ga
Ta = -40°C to +70°C
IP67
IEC – IECEx FMG 14.0028X:
Ex ia IIC T4 Ga
Ta = -40°C to +70°C
IP67
The following approval standards are applicable:
NEMA 250:2003, ANSI/IEC 60529:2004, C22.2 No. 94:2001, C22.2 No. 157:2012, C22.2 No. 213:2012, C22.2 No. 1010.1:2009,
EN60079-0:2018, EN60079-1:2014, EN60079-11:2012, EN60079-26:2015, EN60079-15:2010, IEC60079-1:2014 IEC60079-
11:2011, FM3600:2018, FM3610:2018, FM3611:2018, FM3615:2018, FM3616:2018, FM3810:2018, ANSI/ISA UL60079-
0:2014, ANSI/ISA 60079-1:2009, ANSI/ISA 60079-11:2014, ANSI/ISA 60079-15:2013, ANSI/ISA 60079-26:2017, C22.2 No.
0.4:2017, C22.2 No. 0.5:2016, C22.2 No. 30:2016, CAN/CSA 60079-0:2015, CAN/CSA 60079-1:2016, CAN/CSA 60079-
11:2014, CAN/CSA 60079-15:2016, C22.2 No. 60529:2016, EN 60079-0:2018, EN 60079-26:2015, EN 60079-31:2014, EN
60529:1991+A1:2000+A2:2013, IEC 60079-0:2017, IEC 60079-15:2017, IEC 60079-31:2013
48
Non- Incendive
US/Canada:
FM16US0357X/FM16CA0168X
U.S. - Class I, II, III, Division 2, Group A, B, C, D, E, F, G, T4,
Ta = -40°C to 70°C
CANADA – Class I, Division 2, Group A,B,C,D T4, Ta = -40°C
to 70°C
Class I, Zone 2 AEx nA IIC T4 Gc
Ta = -15°C to 70°C
Class I, Zone 2 Ex nA IIC T4 Gc
Ta = -15°C to +70°C
Type 4X, IP67
ATEX FM14ATEX0060X:
II 3 G Ex nA IIC T4 Gc
Ta = -15°C to +70°C
IP67
IEC – IECEx FMG 14.00028X:
Ex nA IIC T4 Gc
Ta = -15°C to + 70°C
IP67
Dust Ignition Proof
US/Canada:
FM16US0357X/FM16CA0168X
Class II, III, Division 1, Group E, F and G, T4
Ta = 5°C to +70°C
Type 4X, IP67
US/Canada Zone Ratings as follows:
Zone 21, AEx tb IIIC T86C...T120C Ta= -15 C to +70 C Db
(US)
Zone 21, Ex tb IIIC T85C...T120C Ta = -15 C to +70 C Db
(Canada)
Type 4X, IP67
ATEX – FM14ATEX0059X:
II 2 D Ex tb IIIC T85°C ... T120°C Db
Ta = -15°C to +70°C
IP67
IEC – IECEx FMG 14.0028X:
Ex tb IIIC T85°C ... T120°C
Ta = -15°C to +70°C
IP67
SP-ORI-650 Transmisor Magnetostrictivo Jupiter
Modelo JM4
®