9. MAINTENANCE

CAUTION:
• Before cleaning the unit, switch the hot and cold switches to the OFF position and remove
the plug from the power socket.
• Never use corrosive elements or any chemicals to clean this product.
• When the product is not in use, store the unit in a dry place out of direct sunlight.
Cleaning the outside of the water cooler
• To clean the outside of the unit, use a soft cloth with
warm water. Avoid abrasive cleaners or hard materials
to prevent damage and or scratches to the unit.
• Clean the drip tray regularly to avoid water buildup. To
remove the drip tray simply lift it up and outward.
• To clean the back of the machine, clean with a duster such as a micro fiber cloth and/
or vacuum the coils using the duster attachment of the vacuum (please refer to your
vacuum cleaner owner's manual).
Storing your Water Cooler
Please follow these instructions to store the water cooler when it will not be used for an
extended period of time.
• Turn OFF the hot and cold water switches. Unplug the power cord from the power
supply.
• Drain the water through the faucets and draining cap.
• The unit must be stored in the upright position and protected from dust.

10. TECHNICAL SPECIFICATION

Model No
Voltage and Frequency
Rated Total Power
Heating Power
Cooling Power
Heating Capacity
Cooling Capacity
Compressor Refrigerant
HWBL1013 Series
5L/h - ≥90°C (1.32G/h - ≥194°F)
2L/h - ≤ 10°C (0.53 G/h - ≤ 50°F)
Eco Friendly R134a
115V/60Hz
585W
500W
85W
11