EN
2) Data cable RJ9/RJ9
RJ9
1
4
3
2
* Power out specification : 7.5V /30 mA max.
2.3. CommISSIoNINg
To set the motor, use the RS485 SETTING
TOOL ref:9017142A
1
8
2
7
3
6
Connect the RS485 SETTING TOOL to the motor
4
5
switch on and follow the instruction on the RS485
SETTING TOOL (P38).
2.4. TIPS AND RECommENDATIoNS FoR INSTAllATIoN
2.4.1. Questions about the Sonesse 50?
Observations
The motorised
product does not
operate.
The motorised
product is noisy:
6
1: + RS485
2: - RS485
3: Power out *
4: GND
Possible causes
The wiring is incorrect.
The motorisation is in thermal
protection.
An incorrect Data cable has been
used.
The drive wheel and the crown
are not suitable for the tube.
The motorised product is com-
pressed between the brackets
The tube contains swarf and
screws.
RJ9
1: + RS485
2: - RS485
3: Power out *
1
4
3
2
4: GND
1
8
2
7
3
6
4
5
Solutions
Check the wiring and modify it if
necessary.
Wait until the motor cools down.
Check the DAta cable
Replace the drive wheel and the crown
Increase the play between the brackets
Clean the roller tube.
Copyright © 2014 Somfy SAS. All rights reserved.