Makita DUR187U Manual De Instrucciones página 18

Ocultar thumbs Ver también para DUR187U:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
Detachment
The shoulder harness features a means of quick
release.
DUR187U and DUR188U
► Fig.37: 1. Strip
Pull out the strip release the tool from the shoulder
harness.
DUR187L and DUR188L
► Fig.38: 1. Buckle
Simply squeeze the sides of the buckle to release the
tool from the shoulder harness.
MAINTENANCE
WARNING:
Always be sure that the tool is
switched off and battery cartridge is removed
before attempting to perform inspection or main-
tenance on the tool. Failure to switch off and remove
the battery cartridge may result in serious personal
injury from accidental start-up.
NOTICE:
Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
Replacing the nylon cord
WARNING:
Use nylon cord with diameter
specified in "SPECIFICATIONS" only. Never use
heavier line, metal wire, rope or the like. Use rec-
ommended nylon cord only, otherwise it may cause
damage to the tool and result in serious personal
injury.
WARNING:
Make sure that the cover of the
nylon cutting head is secured to the housing
properly as described below. Failure to properly
secure the cover may cause the nylon cutting head to
fly apart resulting in serious personal injury.
1.
Press on the housing latches inward to lift off the
cover, then remove the spool.
► Fig.39: 1. Latch 2. Cover
2.
Prepare approximately 3 m (9 ft) of new nylon
cord. Fold the new nylon cord with one end become
approximately 80 mm (3-1/8") longer than the other
end. Then hook the new nylon cord into the notch in the
center of the spool.
Wind both ends firmly around the spool in the direction
of the head rotation (left-hand direction indicated by LH
on the side of the spool).
► Fig.40: 1. Spool
3.
Wind all but about 100 mm (3 - 15/16") of the
cords, leaving the ends temporarily hooked through a
notch on the side of the spool.
► Fig.41
4.
Mount the spool in the housing so that the grooves
and protrusions on the spool match up with those in the
housing. Keep the side with letters on the spool visible
on the top. Now, unhook the ends of the cord from their
temporary position and feed the cords through the
eyelets to come out of the housing.
► Fig.42: 1. Spool 2. Housing 3. Eyelet
5.
Align the protrusion on the underside of the cover
with the slots of the eyelets. Then push the cover firmly
onto the housing to secure it.
► Fig.43
Replacing the plastic blade
Replace the blade if it is worn out or broken.
► Fig.44
When installing the plastic blade, align the direction of
the arrow on the blade with that of the protector.
► Fig.45: 1. Arrow on the protector 2. Arrow on the
blade
To maintain product SAFETY and RELIABILITY,
repairs, any other maintenance or adjustment should
be performed by Makita Authorized or Factory Service
Centers, always using Makita replacement parts.
18 ENGLISH
Tabla de contenido
loading

Este manual también es adecuado para:

Dur187lDur188uDur188l

Tabla de contenido