Dreiha CoolingBox 65-N Manual página 6

Idiomas disponibles
  • ES

Idiomas disponibles

FQA
Why the refrigerator is not working?
Why food is frozen?
Why water flowing sound is inside the refrigerator?
Why water drops around the refrigerator casing or
door gap?
Why water flowing sound is inside the refrigerator?
What does code F1 mean?
What does code F2 mean?
What does code F3 mean?
What does code FS mean?
What does code F6 mean?
What does code F7&F8 mean?
Warranty & Maintenance
lf your product gets malfunctional, we provide free maintenance for 1 year from the day your purchase, except following situation:
• Contrived damage.
• Catastrophe such as earthquake, conflagration, etc.
• Damage from inappropriate use or violating the instruction.
• Damage from decomposition without following company's instruction.
Technical Data
Question
Model
Rated Voltage
Power Consumption
Capacity
Noise Emission
Temperature Range
Climate Class
Dimensions (W*H*D)
Weight
Testing/ Certification
*Due to product improvement, the technical data might be different
from actual data, please refer to the rated la bel on the product.
Answer
Reason:
• Power supply is malfunctioned.
• The plug and socket are not connected well.
• The fuse has been burnt or not.
• The switch is not on.
• Compressor extended protection for 3mins after switching on.
• Because setting temperature is too low.
• Because it is the flowing sound of refrigerant, which is normal.
• Because it is naturally liquefied and condensed to be water
drops when moisture in the air meets the lower temperature
refrigerator casing.
• Because it is the normal sound of working compressor. The
noise will be reduced after the compressor works stably.
• This is protection mode of low voltage for car, which can be
solved by setting battery protection button from H to M or from
M to L.
• This is the protection mode of overloaded fan. Please turn the
fridge off and restart it after 30mins.
• This is the protection mode of frequent restart of compressor.
Please turn the fridge off and restart it after 30 minutes.
• This is warning code for overheated compressor module. Move
the fridge to a ventilated a rea, turn it off and restart it after
30mins.
• This code mea ns no para meter can be detected by the con-
troller. Please restart the fridge. lf this code shows again, please
contact after-sale department.
• This is the error code of temperature sensor. Please contact us
for more detail.
CBX65-N
DC 12/24V
45W (at 25ºC)
60W (at 43ºC)
65L/2.4 cu.ft
≤45dB
20º - 20º C
T/ST/N/SN
430x630x470 mm
20kg/44lbs
loading

Este manual también es adecuado para:

Cbx65-n