SICK WLD4F 30 00 Serie Instrucciones De Uso página 35

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
11
Technical specifications
Sensing range (with reflector PL40A)
Sensing range max. (with reflector PL40A)
Light spot size / distance
Supply voltage U
B
Ripple
Output current I
max.
Current consumption
Communication mode
IO-Link
Switching frequency
Response time
Enclosure rating
Protection class
Circuit protection
Ambient temperature, operation
1)
Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
2)
Without load. For U
= 24 V.
B
With light / dark ratio 1:1
3)
4)
Signal transit time with resistive load
5)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8025303.1N1Y/2024-03-11 | SICK
Subject to change without notice
connections
OPERATING INSTRUCTIONS
WLD4F
0.02 m ... 4 m
0.01 m ... 5 m (Typ)
Ø 37 mm (1,5 m) (Typ); Ø 48 mm
(2,0 m) (Typ)
DC 10 ... 30 V
1)
≤ 5 VSS
≤ 100 mA
25 mA
2)
COM2
1.1
1000 Hz
3)
≤ 500 μs
4)
IP66, IP67
III
A, B, C, D
5)
–40 °C ... +60 °C
O P E R A T I N G I N S T R U C T I O N S | WLD4F
en
35