Welding using the MIG/MAG method
1) Insert the welding gun cable plug into the Euro MIG/MAG output socket on the front panel of
the machine and tighten it.
2) Insert the ground wire plug into the terminal marked "-" on the front panel of the welding
machine and tighten it clockwise.
3) Insert the polarity change plug into the terminal marked "+" on the welding machine's front
panel and tighten it clockwise.
4) Make sure that the correct welding wire is installed in the machine.
5) Connect the shielding gas cylinder with a pressure reducer to the gas inlet on the rear panel
of the machine using a gas hose.
6) Plug the power cord into an electrical outlet and start the machine.
7) Connect the ground wire to the workpiece. Once these steps are completed, welding can
begin.
Welding using the FCAW method (without gas)
1) Insert the welding gun cable plug into the Euro MIG/MAG output socket on the front panel of
the machine and tighten it.
2) Insert the ground wire plug into the terminal marked "+" on the welding machine's front
panel and tighten it clockwise.
3) Insert the polarity change plug into the terminal marked "-" on the welding machine's front
panel and tighten it clockwise.
4) Make sure that the correct self-shielding welding wire is installed in the machine.
5) Plug the power cord into an electrical outlet and start the machine.
6) Connect the ground wire to the workpiece. Once these steps are completed, welding can
begin.
MMA welding mode:
1) Connect the welding cable to the connection marked with "+" and twist the cable plug to
secure the connection.
2) Connect the ground wire to the connection marked with "-" and twist the wire connector to
secure the connection.
3) Connect the power cord and turn on the power.
4) Connect the ground wire to the workpiece. Once these steps are completed, welding can
begin.
CAUTION! Cable polarity may vary! All polarity information should be described on the
package provided by the electrode manufacturer!
8. Replacing the drive roller
CAUTION! All maintenance, replacement of parts, repairs or adjustments should be carried out with
the power supply disconnected from the device.
If you need to change the wire diameter, also replace the drive roller or adjust the position of the
drive roller.
1) Tilt the pressure adjustment lever to open the pressure roller.