9) MAINTENANCE AND REPAIR
Notices
All maintenance and repair may only be
carried out by sites authorized by the manu-
facturer and exclusively by qualified and suit-
ably trained personnel (refer to the address
list at the back).
WARNING Risk of injury due to acci-
dental actuation of the dispenser and/
or flying device components!
Always disconnect the compressed air supply from
the dispenser during maintenance.
CAUTION Risk of injury from incor-
rect maintenance and repair!
The pneumatic drive unit (refer to item
4 in figure {A} on page II) may never be opened. If it is
necessary to service or repair the pneumatic driving
unit, please contact an authorized Sulzer-Mixpac ser-
vice center (refer to the list of addresses at the back).
NOTICE
Risk of damage due to incorrect
maintenance and cleaning!
Always keep the dispenser clean.
Never use any corrosive cleaning agents for clean-
ing the surface of the device (do not use products con-
taining silicone).
EN
10) TECHNICAL DATA
Operating pressure
Compressed air supply
Compressed air quality
Sound level
Recommended operat-
ing temperature
Relative air humidity
Transport and
storage temperature
Pressure adjustment
Weight
.
8 of 10
680 kPa (6.8 bar) (98 psi) max.
1000 kPa (10 bar) 145 PSI
ISO 8573-1:2010 [2:4:2]
83 dB
+5°C to +40°C
30% to 80% RH
(non-condensing)
0°C to +40°C
infinitely variable
DP2X-200: 1.7 kg
DP2X-400: 2.5 kg
Instruction handbook DP2X