Buffalo 600 Serie Manual De Instrucciones página 5

Máquina para pasta
Ocultar thumbs Ver también para 600 Serie:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
Electrical wiring
There is a danger to life if the wires are incorrectly connected.
Connection to a suitable power supply should only be carried out by a qualified and
competent electrical engineer.
Warning: The fixed wiring of the power cord connection must be equipped with a
disconnect device (leakage protection switch) with a contact distance greater than 30mm
according to the wiring rules.
Connect the unit in accordance with the applicable regulations of your country, federal state, city or local
authority.
Connect the unit to a standard energy supply network.
For a proper electrical connection, adjust the power ratings to the local circumstances and requirements.
Equipotential bonding terminal in electrical appliances is to connect exposed metal and conductive
parts of electrical devices and other devices in electrical appliances with artificial or natural grounding
conductors to reduce potential differences (reduce and prevent the risk of electric shock).
This appliance is supplied unplugged and require hardwiring to a suitable electrical power supply.
CU478 requires a 3400W 230V mono-phase circuit at 50 Hz.
Connect the wires correctly according to their colour coding. This appliance is wired as follows:
Wire colour
Yellow/green
Blue
Brown/grey or black
The appliance must be earthed. If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Electrical wiring (for CU478-E only)
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Connecting the appliance to the mains water supply
Connect a suitable 3/4" water hose to the water inlet located at the back of the appliance and the
mains water supply.
The use of a stop cock is recommended to isolate the unit from the water supply for servicing.
Ensure the water pressure of the connected water supply is between 1.5-6 Bar.
Connecting the appliance to the drain
In case of overflow, there is an overflow hole that sends any excess water to the drain.
Connect a suitable 3/4" hose to the water discharge outlet located at the back right of the appliance.
CU478_ML_A5_v2_20240205.indb 5
CU478_ML_A5_v2_20240205.indb 5
DANGER of electric shock from incorrect connection
Wire function
Earth wire, protective conductor
Neutral wire, neutral conductor
Live wires, Phase L1
To terminals of power supply
Terminal marked E
Terminal marked N
Terminal marked L1
EN
5
2024/2/5 15:15
2024/2/5 15:15
loading

Este manual también es adecuado para: