86
1.3
Technical Specifications
Titrator TitroLine
1.3.1
Translation of the legally binding German version
EMC compatibility according to the Council Directive: 2014/30/EU;
applied harmonized standards: EN 61326-1
Low-voltage directive according to the Council Directive 2014/35/EU;
Testing basis EN 61 010-1: for laboratory equipment
RoHS Council Directive 2011/65/EU
FCC Part 15B and ICES 003
Country of origin: Germany, Made in Germany
The following solvents/titration reagents are allowed to be used:
All common and modern Karl-Fischer reagents can be used for the coulometry process.
Measuring input (μA):
Karl Fischer (Dead-Stop) connector (µA) for double platinum electrode.
Polarisation voltage variably adjustable from 40 ... 220 mV.
Connector: 2 x 4 mm – sockets.
Display:
3.5 inches -1/4 VGA TFT display with 320 x 240 pixels.
Measurement input μA:
Input:
(Dead-Stop-) connector for double platinum electrode (Connection sockets: 2 x 4 mm)
Input for generator electrode (Connection sockets: 2 x 4 mm), colours green (grey) and black
by external multi-range power supply from 100 – 240 V, 50/60 Hz
Power supply:
Input voltage: 12 Volt DC, 2500 mA
Power consumption 30 W
Corresponds to protection class III:
Protection class for dust and humidity IP 50 according to DIN 40 050
manufacturer!
RS-232-C Interface: separated galvanically through photocoupler, Daisy Chain function available
Data bits: adjustable, 7 or 8 Bit (default: 8 Bit)
Stop bit:
Start bit:
Parity:
Baud rate: adjustable: 1200, 2400, 4800, 9600, 19200 (Default 4800 baud)
Address: adjustable, (0 to 15, default: 01)
RS-232-1
for computer, input Daisy Chain
RS-232-2
devices of SI Analytics
- Titrator TitroLine
- Sample Changer TW alpha plus, TW 7400
- Piston burette TITRONIC
- Balances of the types Mettler, Sartorius, Kern, Ohaus, (for more, please contact us)
- Exit Daisy-Chain
USB Interface:
2 x USB-type-A and 1 x USB-type-B
USB-type A
for connecting of USB keyboard, - printer, - manual controller, - data media
(e.g. USB stick) and USB-Hub
USB-type B
for connecting a PC
* The measurement uncertainty of the sensor probe has to be taken into account as well.
®
7500 KF trace
Measurement range I [A]
0 ... 100
Only use the power supply TZ 1853 or a power supply approved by the
adjustable, 1 or 2 Bit (default: 1 Bit)
static 1 Bit
adjustable: even / odd / none
®
:
®
7000 / 7500 / 7500 KF / 7750 / 7800
Display resolution
Measurement accuracy* without sensor probe
0.1
®
300 and 500, TITRONIC
(Release: 21. February 2020)
+/- 0.2 A 1 Digit
®
®
110 plus, TITRONIC
universal,