E-IX. Abnormity and Solution
Fault
Light on, but
motor does not
work
Light does not
work, motor does
not work
Oil leakage
Shake of the body
Insufficient suction
The machine
inclines
Cause
The leaf blocked
The capacitor damaged
The motor jammed bearing
damaged
The internal with of motor off
or a bad smell from the
motor
Beside the above mentioned, check the following:
Light damaged
Power cord looses
One way valve and the air
ventilation entrance are not
tightly sealed
Leakage from the connection
of U-shaped section and
cover
The leaf damaged and causes
shaking
The motor is not tightly
hanged
The body is not tightly
hanged
The distance between the
body and the gas top too
long
Too much ventilation from
open doors or windows
The fixing screw not tight
enough
The hanging screw not tight
enough
www.derkochline.com
Range hoods
Solution
Get rid of the blocking
Replace capacitor
Replace motor
Replace motor
Replace lights
Connect the wires as
per the electric
diagram
Take down the one
way valve and seal
with glue
Take U-shaped section
down and seal with
soap or paint
Replace the leaf
Lock the motor tightly
Fixed the body tightly
Readjust the distance
Close doors and
windows
Tighten the hanging
screw and make it
horizontal
Tighten the hanging
screw and make it
horizontal
36