TOYAMA TG3500iX Guia Del Propietario página 33

Generador digital a gasolina 4t
MAINTENANCE SCHEDULE / CRONOGRAMA DE MANTENIMIENTO / CRONOGRA-
MA DE MANUTENÇÃO
IN THE FIRST 20 HOURS OR 1°
MONTH
• REPLACE OIL ENGINE
• CLEAN THE AIR FILTER
EACH 50 HOURS OR 3 MONTHS
• CLEAN THE AIR FILTER
EACH 100 HOUR OR 6 MONTHS
REPLACE OIL ENGINE
CHECK AND CLEAN THE SPARK
PLUG
EACH 300 HOURS OR 12
MONTHS
REPLACE THE AIR FILTER ELEMENT
REPLACE THE SPARK PLUG*
CHECK AND ADJUST THE VALVE
CLEARANCE*
CLEAN THE TANK AND FUEL
FILTER*
CLEAN THE COMBUSTION
CHAMBER*
VERIFY OR CHANGE ( IF
NECESSARY) THE FUEL LINE*
*THESE SERVICES MUST BE DONE AT AUTHORIZED TOYAMA TECHNICAL ASSISTANCE
*ESTOS SERVICIOS DEBEN SER REALIZADOS EN UNA ASISTENCIA TÉCNICA TOYAMA AUTORIZADA.
*ESTES SERVIÇOS DEVEM SER REALIZADOS NAS ASSISTÊNCIAS TÉCNICAS AUTORIZADAS TOYAMA
EN LAS PRIMERAS 20 HORAS
OU 1° MÊS
• CAMBIAR EL ACEITE DEL MOTOR
LIMPIAR FILTRO DE AIRE
CADA 50 HORAS O 3 MESES
LIMPIAR EL FILTRO DE AIRE
CADA 100 HORAS O 6 MESES
CAMBIAR EL ACEITE DEL MOTOR
VERIFICAR Y LIMPIAR LA BUJÍA
CADA 300 HORAS OU 12 ME-
SES
CAMBIAR EL ELEMENTO DEL FIL-
TRO DE AIRE
CAMBIAR LA BUJÍA DEIGNISIÓN*
VERIFICAR Y AJUSTAR LA ABER-
TURA DE LA VÁLVULA*
LIMPIAR TANQUE Y FILTRO DE
COMBUSTIBLE*
LIMPIAR LA CÁMARA DE COM-
BUSTIÓN*
VERIFICAR Y CAMBIAR ( SI NECE-
SARIO) EL TUBO DE COMBUSTIBLE*
33
NAS PRIMEIRAS 20 HORAS OU
1° MÊS
• TROCAR ÓLEO DO MOTOR
• LIMPAR FILTRO DE AR
A CADA 50 HORAS OU 3 MESES
• LIMPAR FILTRO DE AR
A CADA 100 HORAS OU 6 MESES
TROCAR O ÓLEO DO MOTOR
VERIFICAR E LIMPAR A VELA DE
IGNIÇÃO
A CADA 300 HORAS OU 12 ME-
SES
TROCAR O ELEMENTO DO FILTRO
DE AR
TROCAR VELA DE IGNIÇÃO*
VERIFICAR E AJUSTAR ABERTURA
DA VÁLVULA*
LIMPAR TANQUE E FILTRO DE
COMBUSTÍVEL*
LIMPAR CÂMERA DE COMBUS-
TÃO*
VERIFICAR E TROCAR (SE NECES-
SÁRIO) TUBO DE COMBUSTÍVEL*
loading