T.I.P. CHLOR COMFORT 15000 Traducción De Las Instrucciones De Uso Originales página 20

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
10. Troubleshooting / tips
In the case of malfunction, you should first of all check whether it was caused by an operating error or some other
reason which cannot be attributed to a defect of the device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and tips on their elimination. All
the measures referred to may only be carried out with the pump being separated from the electrical mains. If you
yourself feel unable to eliminate any of these malfunctions, please contact the customer service department or
your point of sales. Any repair beyond the scope specified below must only be performed by qualified staff.
Please bear in mind that all warranty claims will become void in the case of damage caused by inappropriate re-
pair attempts, and that we decline any liability for any ensuing damage.
M
ALFUNCTION
1. The pump is not
1.
No current.
discharging any
liquid, the motor is
not running.
2.
Thermal motor protection feature has
triggered.
3.
The capacitor is defective.
2. The motor is run-
1.
The pump housing is not filled with liquid.
ning, but the pump
is not discharging
any liquid.
2.
Air penetrates into the pump body
3.
Check valve (non-return valve), if pre-
sent, is blocked or defective.
3. The pump stops
1.
The electrical supply does not corre-
after a short time
spond to the information given on the
of operation be-
type plate
cause the thermal
motor protection
2.
Pump or intake openings are blocked by
feature has trig-
solids.
gered.
3.
Temperature of the liquid is too high.
4.
Pump is running dry.
4. Low current
1.
Dirty filter
2.
Blockage in the pipe
5. Noise in the pump
1.
Defect bearing
during the opera-
tion
2.
Air penetrates into the intake line.
3.
Blockage during aspiration
4.
Fault in the impeller
5.
Disturbance while sucking
P
C
OSSIBLE
AUSE
7
Translation of original operating instructions
E
LIMINATION
1.
Please use a device complying with GS
(German technical supervisory authority)
to check for the presence of voltage (safe-
ty information to be observed!). Please
verify the correct position of the plug.
Separate the pump from the electrical
2.
mains, allow the system to cool down,
eliminate cause.
Please contact the customer service de-
3.
partment.
1.
Ensure the water level in the pool is above
the suction point of the pump. Make sure
the strainer is free of dirt
2.
Check to make sure that:
a. the connection points of the intake line
are tight;
b. No siphons (i.e. permanently liquid-filled
loops), kinks, counter-slopes or narrow
spots are present along the intake lines.
3.
Eliminate blocking of the check valve
(non-return valve) or replace, if damaged.
Clean the insert of the pump and check
any blockage of the impeller
1.
Please use a device complying with GS
(German technical supervisory authority)
to check for the presence of voltage (safe-
ty information to be observed!).
2.
Remove possible congestion.
3.
Make sure that the temperature of the liq-
uid being pumped does not exceed the
max. admissible value.
4.
Eliminate causes of dry-running.
1.
clean the filter
2.
Check the pipes. Avoid any bending of
hoses. Flush with sufficient water in case
of need.
1.
Contact your local service partner or the
manufacturer
2.
see section 2 of this table
3.
Check and clean the suction hose
4.
Contact your local service partner or the
manufacturer
5.
Improve the suction inlet. Make sure the
suction inlet is under the water level of the
swimming pool. Reduce the numbers of
screws; assemble a pipe with a larger di-
ameter.
loading