7 . TROUBLESHOOTING
DANGER! Risk of injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before
you troubleshoot the product.
Problem
The system runs after the pump
has been switched off
Pump is running but the delivery
drops suddenly
Control lamp
(Lc)
on the watering
control does not illuminate [ Fig. O2 ]
Control lamp
(Lc)
on the watering
control illumunates red [ Fig. O2 ]
Control lamp
(Lc)
on the watering
control flashes red every second
[ Fig. O2 ]
(Lc)
Control lamp
on the watering
control flashes red every half
second [ Fig. O2 ]
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.
8 . TECHNICAL DATA
Pump
Rated Power
Max. delivery capacity
Max. pressure
Max. delivery head
Max. submersion depth
Max. media temperature
Min. water depth for operation
(approx.)
Weight
Watering Control
Mains voltage
Mains frequency
Rated Power
Output voltage
Max. output current
GAR_01407-20.960.17_2024-06-19.indb 15
GAR_01407-20.960.17_2024-06-19.indb 15
Possible Cause
Drip heads are below the water
survace.
Foot / Filter is clogged.
Watering control is disconnected.
Pump is disconnected.
Pump is blocked (overcurrent).
Container is empty (dry-running
protection).
Unit
Value (Art. 127500.510.00)
W
24
l/h
180
bar
1
m
10
m
1.5
°C
35
mm
15
g
216
Unit
Value (Art. 140700.510.00)
V (AC)
220 – 240
Hz
50
W
40
V (DC)
14
A
2
Remedy
v Place the first drip head above the
water surface.
v Clean the foot / filter.
v Connect the watering control.
v Connect the pump to the watering
control.
v Contact the GARDENA Service.
v Fill the container with water.
15
19.06.24 20:54
19.06.24 20:54