Setting temperature limiter
Prod. no. 36 325, 36 327 and 36 331:
1. Remove screw (F) and detach lever (G), see Fig. [9].
2. Remove screw (H) and remove temperature limiter (I).
3. Remove feather key (J) from temperature limiter (I) and
reinsert in the desired position. The grooves in the
temperature limiter (I) correspond to the temperatures
that can be selected, see Fig. [10].
Assemble in reverse order.
Prod. no. 36 330:
1. Remove screw (K), see Fig. [11].
2. Pull off stop ring (L).
3. Using a screwdriver, turn mixer spindle (M) clockwise
until the desired maximum temperature is reached.
4. Refit stop ring (L) and secure with screw (K).
Applying settings
The infrared electronics provide seven preset programmes for selection. Programme 1 is set at the factory.
Programme
Temporary
shutoff*
Programme 1
Active
Programme 2
Active
Programme 3
Active
Programme 4
Active
Programme 5
Active
Programme 6
Inactive
Programme 7
Inactive
* Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, water flow is not started for 3 minutes
even if an object is detected.
** Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is initiated
for a duration of 5 minutes after 24 hours (usage-independent) or for a duration of 1 or 5 or 10 minutes after 72 hours (usage-
dependent) after the fitting was last used.
Safety note:
Ensure free draining in the case of activated automatic flushing.
The fitting can be individually programmed using the remote control (see Special accessories, prod. no.: 36 206).
Operation
The infrared electronics emit invisible, pulsed light.
The sensor system is adjusted so that water flow is initiated
when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s of continuous detection of an object, the infrared
electronics automatically stop the water flow.
Automatic flushing**
On/off
Flush interval Flush duration
-
Off
On
72 h
On
24 h
On
72 h
On
72 h
Off
-
On
72 h
Usage-dependent/
independent
-
-
5 min
Usage-dependent
5 min
Usage-independent
10 min
Usage-dependent
1 min
Usage-dependent
-
-
5 min
Usage-dependent
Duration
of thermal
disinfection
3.5 min
3.5 min
11 min
3.5 min
3.5 min
3.5 min
3.5 min
6