the area around the equipment shall be surveyed to make sure that there are no flammable
hazards or ignition risks."No Smoking" signs shall be displayed.
 Checking for presence of refrigerant, The area shall be checked with an appropriate refrigerant
detector prior to and during work, to ensure the technician is aware of potentially toxic or
flammable atmospheres. Ensure that the leak detection equipment being used is suitable for
use with all applicable refrigerants, i.e., no spark, adequately sealed, or intrinsically safe.
 Ensure that the area is in the open or that it is adequately ventilated before breaking into the
system or conducting any hot work. A degree of ventilation shall continue during the period
that the work is carried out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
 Where electrical components are being changed, they shall be fit for the purpose and to the
correct specification. At all times, the manufacturer's maintenance and service guidelines shall
be followed. If in doubt, consult the manufacturer's technical department for assistance.
Detection of flammable refrigerants: Under no circumstances shall potential sources of ignition
be used in the searching for or detection of refrigerant leaks. A halide torch (or any other
detector using a naked flame) shall not be used.
Ⅲ、Transportation and Placement
Transportation:
1. Take out packing and clean all the cabinet using warm water together with 5% of neutral soap then
dry it with a soft-cloth; for the glass parts only use specific products, avoiding the use of water which
can leave on the glass limestone residues.
2. Keep a distance from the wall of 10 cm at least. Please level the unit by settling the adjustable feet.
3. Cabinet must be installed on a perfectly even surface, far away from any heat source included sun
ray.
4. Do not install the unit in open places and do not expose it to rain.
Note: schematic diagram for demand size of product space
Choosing the installation location:
The unit is for indoor application only.
Due to the fact that the unit has a glass door, its performance is highly influenced by environmental
conditions. To minimize the environmental effects on the unit's performance, the following are
recommended:
 The unit is not to be placed near any kind of heat source
 The unit is not to be placed near or inside air streams produced by ventilation fans, open doors
6
loading