3 Phase Power:
Ideally, the power converter should be supplied with 380V to 480V three phase power for maximum
performance. If the plug does not match the available outlet, a suitable plug can be mounted by a qualified
electrician.
Single Phase Power
In situations where 3 phase power is not available, this machine may also be run on 220V to 240V single phase
power with slightly reduced power. Use the single phase adaptor cable. Using the single phase adaptor cable,
the current is limited to 16A.
If more power is needed, and a 32A or larger breaker is available, the main plug may be removed, and the
converter's main power supply cable may be directly wired to the breaker. In this case, connect the L1 and
L2 wires to the breaker, leaving the L3 wire unconnected. Then connect the earth (ground) wire to the earth
connection.
NOTE: The above action may only be performed by a qualified electrician.
Power Supply Connections: Three Phase and Single Phase
Ø ~ 380V - 480V
3
CONVERTE R
Ø~ 220V - 240V
1
CONVERTE R
Ø~ 380V - 480V
3
Converter Supply Cable
BROWN
BLACK
GREEN / YELLOW
CEE 16A 480V
3P + N + E
PLUG
CEE 16A 480V
3P + N + E
PLUG
CEE 16A 5P
Male Plug
L1
L2
L3
GREY
PE
N
GB
CEE 16A 480V
3P + N + E
CONNEC TOR
Ø~ 220V - 240V
1
CEE 16A 5P
Ø~ 220V Adaptor Cable
1
Female Connector
L1
BROWN
L2
L3
PE
GREEN / YELLOW
N
8
Ø ~ AD APTOR
1
CABLE
2P + E
L/+
N
BLUE
PE