After the pump is primed and flowing water at a steady
pressure you should open a few faucets and adjust the
pressure control valve to the pressure listed in the chart.
To increase pressure close the valve. See Chart 1.
COMPLETING THE INSTALLATION
COMPLETING THE INSTALLATION
Install Enduro Water System Tank
While the tank is empty check the pre-charge
WARNING
air pressure with a tire pressure gauge. The
tank pre-charge should be set 2 psi lower than
the pump cut-in (turn on) pressure. On Red
Jacket Water Product tanks the valve cap is the
Hazardous pressure can
cause personal injury or
property damage.
primary seal so be sure to re-install the cap
after checking air pressure. Avoid frequent air checking
as you lose 1 – 2 psi every time you check. Red Jacket
Water Product jet pumps are all supplied with 20 – 40 or
30 – 50 psi standard pressure switch settings.
Locate the tank on a firm, level surface.
A pressure relief valve is recommended for all systems,
and mandatory for systems producing over 100 psi. It
should be rated less than 100 psi but greater than the
system pressure near the tank.
Make the piping connection between the pump discharge
and the tank. Complete the piping by connecting to the
house plumbing.
Note: Red Jacket Water Products only sells the Enduro
Water System tanks. They are all shipped with a tank
installation guide in the carton, please refer to it for more
detailed tank instructions. If you are using a tank from
another manufacturer please contact that company for
specific instructions on their tank.
Galvanized tanks are installed the same as pre-charged
tanks except they require an Air Volume Control (AVC)
to replenish air lost through absorption. The AVC
requires connection to a vacuum port on the pump. The
suction side of the AVC must have a minimum 3"
vacuum for 15 seconds when the pump starts. Follow the
instructions provided with the air volume control.
Priming a Shallow Well System
Priming means filling the pump and suction pipe with
water. Most shallow well jet pumps handle air well and
will evacuate air from the suction line but it may take
several minutes to prime depending on depth to water,
and pipe size and length.
VENT THE PUMP FOR EASIER PRIMING !
It is easier to prime a pump if you allow all the air to
escape from the pump and the pipes, the water cannot go
in unless the air can escape!
Remove the pipe plug or pressure gauge bushing in the
discharge tee to fill the pump with water. On shallow
well pumps you should remove the
between the suction and discharge ports to allow air to
escape as you fill the casing with water. The port will be
located on either the top of the casing or the top of the
shallow well adapter. Fill the pump and as much of the
suction pipe as possible with water through the discharge
port.
Replace the
1
" pipe plug and discharge gauge/bushing.
8
Open the faucet closest to the pump/tank a small amount
to allow air to escape the system. Do not open it too
much or the pump will expel too much water and you
will have to reprime the pump casing. On jobs with long
suction pipes you may have to add water to the pump
casing several times to complete the priming process.
Go to Power Motor.
Priming a Deep Well System
Priming a deep well system means filling the pump and
the suction/pressure pipes with water. Deep well single
stage and multi-stage pumps require a complete prime
before starting. Filling the pipes with water before
installing the pump will make priming faster and easier.
VENT THE PUMP FOR EASIER PRIMING !
To insure a complete prime we recommend removing
the angled
1
" vent plug located just above the suction
8
pipe on horizontal pumps. This will allow the air to
easily escape as water enters. Our horizontal convertible
deep well jets should be primed through a tee at the
pump discharge. The tee is not supplied by Red Jacket
Water Products.
1
" pipe plug located
8
5