points, and cause motor damage if not corrected. If for
any reason you must have fittings or filters between the
pump and tank and they cause switch chatter you should
move the pressure switch to the tank cross tee. Go To
"Install Enduro Water System Tank" to Complete
Shallow Well Installation.
DEEP WELL DOUBLE (TWIN) PIPE
DEEP WELL DOUBLE (TWIN) PIPE
start here
Double (Twin) Pipe Suction Piping
A double (twin) pipe jet assembly is used in wells 4" and
larger. Our 4" jet assemblies require a minimum 1
suction and 1" drive water pipe. Use of smaller piping
will reduce performance in gpm and pressure. Offsets
over 50' require larger pipes to reduce friction loss and to
obtain published performance.
Install Double (Twin) Pipe Jet Assembly
WARNING
Check to make sure the nozzle is installed in
the jet assembly. Install the venturi tube in line
with the nozzle. On 4" jets attach the 1
suction and 1" pressure pipe to the jet assembly
Hazardous pressure can
cause personal injury or
property damage.
female threads. Install a foot valve on the male
thread bottom port on the jet assembly or on the end of a
34' tail pipe. The tail pipe prevents over pumping a low
yield well so the pump will not break suction. See Tail
Pipe in Technical Section.
Lower the jet assembly into the well. It should be set at
least 5' below the static water level. Keep the jet a few
feet off the well bottom to lessen the possibility of
sucking debris into the jet. The connections at the well
head can be either a pitless adapter or a well seal.
Priming will be easier if you fill the pipes with water
before attaching the pump.
Connect the suction and pressure pipes to the threaded
connections on the face of the pump. This can be done
using unions and threaded pipe nipples, or barbed
connectors with poly pipe. Always double clamp barbed
connectors. Make sure that the piping slopes upward to
the pump and that no point is above the pump suction.
On long offsets it is easier to prime the system if you fill
the pipes with water before connecting the pipes to the
pump. Go to Deep Well Discharge Piping.
DEEP WELL SINGLE PIPE (PACKER)
DEEP WELL SINGLE PIPE (PACKER)
SYSTEM
SYSTEM
– start here
Single Pipe Deep Well Jet (Packer) Suction Piping
Packers use the area between the well casing
WARNING
and the suction pipe as the drive water
(pressure) pipe. The 2" or 3" well casing must
be smooth and clean to insure a good seal with
the packer leathers or the system will leak and
Hazardous pressure can
cause personal injury or
property damage.
not hold prime. The 2" packer requires 1
threaded suction pipe and the 3" requires 1
packers only: Use the Red Jacket Water Products turned
couplings part #64655 to connect the sections of 1
threaded pipe. This special diameter turned coupling
increases the clearance between the 2" well I.D. and the
O.D. of the coupling to allow the drive (pressure) water
to easily pass the couplings. Failure to use them will have
a negative impact on pump performance, both pressure
and gpm will decrease. The pump may easily lose prime
while pumping due to the restriction!
4
Using smaller than recommended pipe may reduce gpm
output. The longer the pipe the worse the affect.
Install Single Pipe (Packer) Assembly
To ease installation soak the 2" or 3" packer assembly in
warm water to make the leathers soft and pliable. DO
NOT lubricate them with grease, oil, or petroleum jelly!
The leathers must absorb water to seal the packer
assembly against the well casing.
Check to make sure the nozzle is installed in the jet
assembly. Install the venturi tube in line with the nozzle.
1
"
Install a strainer (not supplied with packer assembly) on
4
the bottom port of the packer assembly or on the end of
a 34' tail pipe. The tail pipe prevents over pumping a low
yield well so the pump will not break suction. Attach the
packer assembly to the suction pipes using the Red Jacket
Water Products turned couplings to connect the sections.
Insert the single pipe (packer) assembly into the well
casing and push it down. Attach the other pipe sections
as you lower the jet into the well. See Tail Pipe in
1
"
Technical Section.
4
Attach Suction Pipe To Right Angle (Packer) Adapter
Single pipe (packer) systems always require a packer
adapter at the well head. The adapter makes the
transition from vertical to horizontal. See the list of
packer adapters/pump models to see which one your
pump system requires. See Chart 1 for a list of Packer
Adapters/Pump Models.
After the jet assembly is inserted into the well, attach the
Packer Adapter to the top of the suction pipe. Screw the
top section of 1
threaded adapter into the 1
in the 2" packer adapter or a 1
3" packer adapter.
Make sure that the O.D. of the well casing is free of dirt
and burrs. With the gland bolts loosened the tapered seal
ring on the packer adapter should slide over the well
casing. After insuring that it is in place tighten the two
gland nuts to compress the seal ring and seal it to the
well casing O.D.
Install the pump by attaching it to the Packer Adapter
using the bolts and gaskets provided.
DEEP WELL DISCHARGE PIPING
DEEP WELL DISCHARGE PIPING
WARNING
Hazardous pressure can
cause personal injury or
property damage.
pump and the first discharge port. It is best to locate it as
1
"
4
close to the pump as possible. Failure to install and adjust
1
". On 2"
2
a pressure control valve will result in loss of prime during
peak usage such as filling a washing machine, bathtub or
1
"
4
using outside hose bibs.
All DRJ pumps can use a simple gas cock, a full port ball
valve, an AV15 or an RJAV22 as a pressure control valve.
1
" male threaded suction pipe or a
4
1
" NPT female threaded hole
4
1
" suction pipe into the
2
All deep well jet pumps require back pressure
to operate the jet assembly. To insure we have
the required back pressure or drive water
pressure we must use a pressure control valve
or some type of flow restrictor in the discharge
line. The valve must be located between the
loading