Changing Oil (See Fig 21)
•
Run the Generator until the Engine is warm.
•
Place generator on a level surface.
•
Remove the crankcase dipstick.
•
Place an oil pan underneath the oil drainage bolt to collect used oil.
•
Remove the oil drainage plug and allow oil to drain completely.
•
Reinstall oil drainage plug, tighten securely.
•
Carefully add SAE 10W-30 to empty reservoir until the oil reaches the
outer edge of the oil fill hole (Crankcase Dipstick hole).
•
Replace crankcase dipstick.
Oil Recommendations
•
Do not use special additives.
•
Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.
Note:
*
Below 40
F
*
*
Above 80 F
Check oil level more frequently.
F
104
*
86
68
50
32
14
-4
-22
(4 C ) the use of SAE 30 will result in hard starting.
(27 C )
the use of 10W-30 may cause increased oil consumption.
MAINTENANCE
*
*
19
Oil Fill & Dipstick
Oil drainage plug
Fig 21
C
40
30
20
10
0
-10
-20
-30