Changing Oil (See Fig 21)
Run the Generator until the Engine is warm.
Place generator on a level surface.
Remove the crankcase dipstick.
Place an oil pan underneath the oil drainage bolt to collect used oil.
Remove the oil drainage plug and allow oil to drain completely.
Reinstall oil drainage plug, tighten securely.
Carefully add SAE 10W-30 to empty reservoir until the oil reaches the
outer edge of the oil fill hole (Crankcase Dipstick hole).
Replace crankcase dipstick.
Oil Recommendations
Do not use special additives.
Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.
Note:
*
Below 40
F
*
*
Above 80 F
Check oil level more frequently.
F
104
*
86
68
50
32
14
-4
-22
(4 C ) the use of SAE 30 will result in hard starting.
(27 C )
the use of 10W-30 may cause increased oil consumption.
MAINTENANCE
*
*
19
Oil Fill & Dipstick
Oil drainage plug
Fig 21
C
40
30
20
10
0
-10
-20
-30
loading