Install function unit, see figs. [1] to [6].
Observe printing on the lid.
1. Prepare holes for the function unit as well as slots
for the pipes and vacant tubes, see fold-out page II,
figs. [1] and [2].
2. The vacant tube (6m) provided must be used when
connecting the function unit to the plug power supply.
When using faucet 36 054, a vacant tube must be
additionally routed to the concealed faucet body 36 075,
see fig. [2].
3. Unscrew screws and remove lid, see fig. [3].
4. Align and fasten function unit in place, see fig. [4].
Do not solder the connections.
5. The cold water supply must be connected to the inlet
marked COLD, the hot water to the inlet marked HOT,
see fig [5].
6. Route mixed water outlet to the faucet.
7. Route connecting cable for plug power supply in vacant
tube, see fig. [6].
When using faucet 36 054, additionally route the connecting
cable to the faucet in vacant tube. Break out the pre-
stamped hole from the function unit for this purpose.
Several connecting cables can be connected together,
see Replacement parts, fold-out page I.
8. Secure the vacant tubes in the function unit with clips (A).
Flush the function unit
Do not apply voltage to the function unit prior to flushing, as it
is open in the delivery condition.
Open hot and cold water supply and check connections
for leakage.
1. Open isolating valves (C), see fig. [7].
Flush piping system prior and after installation of faucet
thoroughly!
2. Connect the supply voltage, see fig. [7].
3. Fit lid and fasten with screws, see fig. [3].
English
Maintenance
Inspect and clean all components and replace if necessary.
Disconnect power supply.
Close isolating valves.
I. Function unit, see figs. [3], [7] and [8].
1. Unscrew screws and remove lid, see fig. [3].
2. Disconnect plug-in connectors, see fig. [7].
3. Unscrew union nut (B) and seal (D), see fig. [8].
4. Remove clip (E) and detach function unit (G).
II. Thermistor, see Fig. [8].
1. Disconnect plug-in connector (H).
2. Unscrew nut (I) and pull out thermistor (J).
III. Battery, see fig. [9].
The battery must be replaced 10 years after commissioning
the faucet, at the latest.
Install in reverse order.
Replacement parts
See fold-out page I (* = special accessories).
Disposal note
Dispose of batteries in accordance
with national regulations.
2